TOA Electronics N-VR2010 Home Security System User Manual


 
13
IN
12V OUT
AUDIO ADJ.
PHANTOM
MIC
LINE
ON
NC
VIDEO
VOL
RS485
CONTACT
LINE
IN
OUT
MIC IN
CONTACTCONTACT
IN
OUT
RS485
12
C
12
C
+
RS-232C
24V
OUT
1
2
AUDIO
DE
UT
VIDEO OUT
Monitor
Network
Video Receiver
N-VR2010
VIDEO IN
Connect the 24 V AC or 24 V DC
when not using a PoE-compatible hub.
Note: Connect the 12 V DC terminal when using a remote controller.
Remote Controller
C-RM500
RS-485(
+
) RS-485(
-
)
DC12 V
RS-485
Rear
8.7. Serial Port
[RS-232C]
Use a null modem cable such as the YR-S2320 when connecting control terminals of the remote controller to
this terminal. No RS-232C connector plug is supplied with the unit.
[RS-485]
Connect the control terminal of the remote controller to this terminal.
Applicable cable
Solid cable: AWG28 (Ø 0.32 mm) - AWG22 (Ø 0.65 mm)
Stranded cable: AWG28 (0.08 mm
2
) - AWG22 (0.32 mm
2
)
Note
Strip the cable sheath approximately 10mm, then insert the cable while pushing down on the terminal button
with a screwdriver.
RS-232C Connector D-sub 9P
1 2 3 4 5
6 7 8 9
1
2
3
4
5
6
7
8
9
Unconnected
RXD (Reception data)
TXD (Transmission data)
Unconnected
GND
Unconnected
RTS (Transmission request)
CTS (Transmission permission)
Unconnected
Both the RTS and CTS pins are internally shorted.
No.
Terminal name