Thermo Products omd-70 Furnace User Manual


 
All installations and services must be performed by qualified service personnel.
B. COMPONENT LOCATIONS
The following diagram shows a typical furnace installation and typical position of the
components referenced in these instructions.
Figure 9.
C. INSPECTION AREAS
IMPORTANT: For safe operation it is the responsibility of the owner and/or user that the
burner, chimney/vent pipe, heat exchanger and controls should be inspected every year by
a qualified heating contractor.
1. VESTIBULE: The furnace vestibule areas or burner compartment should be
inspected by opening the lower front door of the furnace and looking for signs of
excessive heat such as discoloration of components, materials damaged from rust or
corrosion, soot or carbon build-up.
44