Thermo Products OH6 Furnace User Manual


 
Specifications
1. Output based on Annual Fuel Utilization Efficiency rated by manufacturer.
2. Seasonal Efficiency (also called AFUE - Annual Fuel Utilization Efficiency) ratings are based on tests following the U.S. Department of Energy
test procedures.
3. To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is required.
Form No. PL81410041003 - 1/07 - 10Ms
Printed in the U.S.A.
© 2007 ermo Poducts, LLC - North Judson, IN
Phone: 574-896-2133
www.thermopride.com
Model Number OH6FX072DV4R
Heating Capacity Low Capacity High Capacity
Low Fire High Fire Low Fire High Fire
Heat Input Rate (BTUH)
70,000 85,000 85,000 106,250
Output BTUH
1
61,500 74,000 74,000 91,000
Seasonal Efficiency
2
(AFUE) 87.3 86.4
Largest Recommended A/C
3
4 Tons 4 Tons
Nominal Temperature Rise 64° 64° 64° 64°
Dimensions (inches) H x W x D 45” x 20” x 30”
Nominal Flue Outlet Diameter 5”
Approximate Shipping Weight (lbs.) 250
Quantity and Size of Permanent Filters (1) 24-3/4” x 15-3/4”
Electrical Requirements 120 / 60 / 1
Maximum Fuse Size /ECM 15
Total Current (AMPS) /ECM 12.3
Height from Floor to Center of Flue 40-3/4”
Supply Air Outlet Size W x D 18” x 19”
Return Air Ductwork Connection
Flange Size on Filter D x H
24-1/2” x 15”
Return Air Inlet Opening Size in Side
Casing (to be cut-out by dealer) D x H
23” x 14”
Accessory Items
Programmable Thermostat 350866
R
2-Stage Burner Easy Setup
e 2-Stage burner is easy to set up and service. Your
contractor merely moves a pin and adjusts it for
low fire as with a traditional burner, then moves the
pin again and sets it up for high fire. Lastly, he will
move the pin to the third setting to run. e burner
will then switch from low to high fire automatically
as needed. e burner is also mounted on a double
hinge making it easy to service as needed.