Thermo Products CMA3-75D36N Furnace User Manual


 
All installations and services must be performed by qualified service personnel.
MODEL
CMC1-50DV3
CMC1-75DV3
INPUT IN BTUH
50,000
75,000
OUTPUT IN BTUH
48,000
72,000
MAIN ORIFICE-NAT.
#42
MAIN ORIFICE-LP
#54
GAS SUPPLY PRESSURE
L.P. MINIMUM
11” IN.W.C.
NAT. MINIMUM
4.5”IN.W.C.
L.P. MAXIMUM
14” IN.W.C.
NAT. MAXIMUM
14” IN.W.C.
GAS MANIFOLD PRESSURE
L.P.
10.0” + .03 IN.W.C.
NAT.
3.5” + .03 IN. W.C.
INTAKE SIZE IN INCHES
2”
VENT SIZE IN INCHES
2”
NOMINAL TEMPERATURE RISE
55°F
65°F
SEASONAL EFFICIENCY (AFUE*)
95%
*ANNUAL FUEL UTILIZATION
EFFICIENCY
DIMENSIONS
CABINET SIZE
WIDTH 18” DEPTH 25-3/4" HEIGHT 57"
SUPPLY AIR OUTLET
WIDTH 12” DEPTH 12"
ELECTRICAL SUPPLY
115 VOLTS-- 60HZ --1/PH
FUSE OR HACR BREAKER
15 AMPS
TOTAL CURRENT AMPS
7.15 AMPS
NOMINAL ANTICIPATOR SETTING
0.8 MILLIAMPS
FILTER SIZE
(1) 18” X 24” X 1”
APPROXIMATE SHIPPING WEIGHT
195 LBS.
205 LBS.
BLOWER DATA
BLOWER MODEL
12-9T DIRECT DRIVE
MOTOR HORSEPOWER
1/2 ECM
MOTOR RPM
1075 (HIGH SPEED)
CFM @ .2 & .5 IN. W.C. SPEED
.2”
.5”
|
.2”
.5”
LOW
639
437
|
935
802
MD-LOW
834
653
|
998
880
MED
948
811
1113
1007
MD-HIGH
1145
1026
|
1177
1083
HIGH
1365
1265
|
1272
1177
FOR BURNER COMBUSTION INFORMATION REFER TO INITIAL STARTUP.
9