Table 2: Burner Specifications and High and Low Fire Heating Performance
Heating
Mode
Oil Pump
Pressure
(PSIG)
Oil
Flowrate @
Nozzle
(GPH)
Heat Input
Rate*
(BTUH)
Heat
Output
Rate**
(BTUH)
Burner Model
Number
Air Tube
Combination
Nozzle
Type
High Fire 130
2
0.75
105,000 85,000
Low Fire 120
1
0.6
85,000 67,000
AFG-TP1502 AF42 BNHSSS
Simplex, 80
deg., hollow
cone
* Based on #2 fuel (domestic heating) oil having higher heating value of 140,000
BTU per gallon.
** Based on an assumed steady state, thermal efficiency of 80%.
1
Factory installed.
2
Provided by installer.
For more specific burner information, consult the Model AFG Oil Burner
Instruction Manual or contact Thermo Products, LLC. P.O. Box 217, North
Judson, IN 46366. Phone no. 574-896-2133.