Wiring
Important - Because of the motorized doors, wiring the HV is different than a normal ON/OFF fan. Please follow the
instructions carefully. Be sure to turn off power before wiring the HV Whole House Fan It is recommended that the
wiring of the HV be done by a licensed electrician.
The HV requires a constant source of power. Because the doors are motorized, they need power to open and power to
close. The fan operation is controlled internally.
HV1000
There are three wires in the electrical box:
WHITE, RED, and BLACK.
• Connect the WHITE wire to Line Neutral
• Connect the RED wire to Line Hot
• Connect the BLACK wire to a Switched Hot Feed
When 115 VAC Hot is applied to it, the doors will
open. When 115 VAC Hot is removed, the doors will
close.
• Connect the ground wire to the screw in the electrical
box
Drawing is not to scale
HV1600
The HV1600 is connected to power through the line cord
and must be plugged into a constant, grounded power
source. When connected to power, it will be fully functional
with the hand held remote control unit. When any of the
buttons on the remote control are pushed, the red indicator
light should momentarily flash.
Optional Controls:
Hardwiring the unit to wall switches using the BLUE and
YELLOW wires will provide additional, manual control. The
BLUE wire will provide on/off control and the YELLOW wire
will provide high or low speed control. Using a switch in the
ON position will override the remote control function.
Use only SPST (single pole, single throw) switches.
Drawing is not to scale
The HV whole house cooling fans are not for use with solid state speed controls
A Remote Control Kit for the HV1000 is available and may be purchased separately. Installation is quick and easy
and it may be installed at any time.
Care
All the motors in the HV are permanently sealed and do not require oiling. To keep dirt, dust and debris from the fans we
recommend that you periodically remove the grille from within the living space and dust the fan blades. Please remember
to make sure that the fan is OFF before dusting the fan blades.
Specifications
Voltage …………………………….
Power
HV1000…………..….......
HV1600…………..….......
Airflow @ .03” (System)
HV1000 …………...…….
HV1600 High……..…….
HV1600 Low ……………
115VAC 60 Hz
112 Watts
276 Watts
1000 CFM
1600 CFM
900 CFM
R-Value
HV1000 & HV1600-GR
HV1000-DB & HV1600-GDR
Weight
HV1000………………….
HV1600…………………
Rough Opening……………………
Grille Dimensions………………….
Grille Color ………………………...
R-22
R-38
17 Lbs.
21 Lbs.
14 ½” x 22 ½”
15 ¾” x 25 ¾”
White