NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INSTALLATION ACCESSORIES
The following accessory items are available for
use in the installation of this appliance.
Outside Air Kits Models FOAK-4 and FOAK-4LD
Outside Air kits are available with duct (FOAK-4)
and without duct (FOAK-4LD) for use if outside
combustion air is required or desired. If model
FOAK-4LD is used it must be used in conjunction
with locally purchased, non-combustible Class 1
or Class 0 flexible duct.
Wall Switch Kit 85L87 FWSK
Outside Combustion Air Kits
(with duct) 81L87 FOAK-4
(without duct) 81L88 FOAK-4LD
COLD CLIMATE INSULATION
If you live in a cold climate, seal all cracks
around your appliance with noncombustible
material and wherever cold air could enter the
room. It is especially important to insulate
outside chase cavity between studs and under
floor on which appliance rests, if floor is above
ground level.
A hearth extension is not required with this
appliance. Any hearth extension used is for
appearance only and does not have to conform
to standard hearth extension installation re-
quirements.
Note: Combustible wall finish materials and/or
surround materials must not be allowed to
encroach the area defined by the appliance
front face (black sheet metal). Never allow
combustible materials to be positioned in front
of or overlapping the appliance front face.
FINISHING REQUIREMENTS
Wall Details and Combustible Mantels
Complete finished interior wall. To install the
appliance facing flush with the finished wall,
position framework to accommodate the thick-
ness of the finished wall
(Figure 25 )
. This
figure also indicates vertical installation clear-
ances to combustible mantels.
Figure 26
also
shows an example of a combustible mantel
shelf projecting a maximum of 12" (305 mm)
from the wall, and which must be installed a
minimum distance of 15 ³⁄₄" (400 mm) from
the top of the firebox opening.
Figure 26
Figure 25
Fireplace
Opening
Spacer
Finished
Wall
Header
123456789
1011
12
8
9
10
11
12
Combustible
Mantel Clearances
Inches
Min. Height of Mantel
Above Fireplace
Opening
Max.Length of Mantels
Three mantels are shown (dark gray elongated rectangles)-
one, 1¹⁄₂ in. long at a min. of 6 in. above the fireplace opening;
the second, 8 in. long at a min. of 12 in. above the fireplace opening;
the third, 12 in. long at a min. of 15 ³⁄₄ in. above the fireplace opening;
for any mantels between these three in length, they must be located
within the lighter gray shaded area.
0
0
1¹⁄₂
7
6
13
14
15
15³⁄₄
64"
(1626 mm)
Min. to
Ceiling
15 ³⁄₄ " Min.
(400 mm)
0" (0 mm) Clearance
to Combustible
Side Wall
Max. Projection 12" (305 mm)
Combustible
Mantel