Superior B-40REN Indoor Fireplace User Manual


 
12
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
In Canada
THE CONVERSION SHALL BE CARRIED OUT
IN ACCORDANCE WITH THE REQUIREMENTS
OF THE PROVINCIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE CAN1-B149.1
AND .2 INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EFFECTUÉE
CONFORMÉMENT AUX RECOMMANDATIONS
DES AUTORITÉS PROVINCIALES AYANT
JURIDICTION ET CONFORMÉMENT AUX
EXIGENCES DU CODE D'INSTALLATION CAN1-
B149.1 ET.2.
Gas conversion kits are available to adapt your
appliance from the use of one type of gas to the
use of another. These kits contain all the nec-
essary components needed to complete the
task including labeling that must be affixed to
ensure safe operation.
Kit part numbers are listed below and the follow-
ing steps detail the conversion procedure.
Millivolt Conversion Kits
Honeywell
75L28 Natural to Propane
75L27 Propane to Natural
SIT
H2021 Natural to Propane
H2022 Propane to Natural
Electronic Conversion Kits
75L29 Natural to Propane
75L26 Propane to Natural
Step 1. Turn off the gas supply to the appliance.
Remove the front glass door/frame (if used) from
the appliance.
Step 2. Carefully remove the front log. Exercise
care as not to break the log.
Step 3. Remove the access panel. Locate the
screws securing the burner (tray) to the appli-
ance. Remove the burner and retain the secur-
ing screws.
Millivolt Appliances
Step 4. SIT Systems - See
Figure 27
and the
instructions provided with the kit. Using a Torx
T20, remove and discard the three pressure
regulator mounting screws. Remove the pres-
sure regulator, spring, poppet, diaphragm and
bushing. Discard all removed components.
Ensure the rubber gasket installed on the back
of the replacement pressure regulator is prop-
erly positioned and install the new pressure
regulator using the new screws supplied with
the kit. Tighten screws to 25 In. lb. torque.
Step 5. Honeywell Systems - See
Figure 28
and the instructions provided with the kit.
Remove the black thread-protecting cap. Re-
move the conversion flip cap by turning it
counterclockwise.
Figure 27
Gas Conversion Kits
WARNING: THIS CONVERSION KIT SHALL BE IN-
STALLED BY A QUALIFIED SERVICE AGENCY IN
ACCORDANCE WITH THE MANUFACTURER'S IN-
STRUCTIONS AND ALL APPLICABLE CODES AND
REQUIREMENTS OF THE AUTHORIZED AGENCY HAV-
ING JURISDICTION. IF THE INFORMATION IN THESE
INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A
FIRE, EXPLOSION OR PRODUCTION OF CARBON
MONOXIDE MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE. THE
INSTALLATION IS NOT PROPER AND COMPLETE
UNTIL THE OPERATION OF THE CONVERTED APPLI-
ANCE IS CHECKED AS SPECIFIED IN THE OWNER
INSTRUCTIONS SUPPLIED WITH THE KIT.
AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION
SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE
CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET
TOUTES EXIGENCES ET CODES APPLICABLES DE
L'AUTORISÉS AVOIR LA JURIDICTION. SI L'INFORMATION
DANS CETTE INSTRUCTION N'EST PAS SUIVIE
EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE
PROTOXYDE DE CARBONE PEUT RÉSULTER LE DOMMAGES
CAUSER DE PROPRIÉTÉ, PERTE OU BLESSURE
PERSONNELLE DE VIE. L'AGENCE QUALIFIÉE DE SERVICE
EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET
ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET
COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL
CONVERTI EST CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS
DANS LES INSTRUCTIONS DE PROPRIÉTAIRE
PROVISIONNÉES AVEC L'ÉQUIPEMENT.
Figure 28
Pressure
Regulator
Remove
These
Components
Flip Cap
Thread
Protector
Invert the flip cap so that the letters associated
with the desired gas type are positioned closest to
the valve body. NG is for natural gas and LP is for
propane. Tighten the flip cap by turning it clock-
wise. Replace the black thread-protecting cap.