Sunbeam 644 Humidifier User Manual


 
6. If humidifier does not start immediately, make sure humidifier is
plugged in. If a wet area forms around your humidifier, the room
air is at maximum humidity; unplug and empty your humidifier.
To reduce the risk of electric shock, this appliance has a polarized plug
(one blade is wider than the other). This plug will fit in a polarized outlet only
one way. If the plug does not fit fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician to install the proper outlet. Do
not change the plug in any way.
HUMIDIFIER IMPELLER TIP
This humidifier contains a removable moisture
Impeller Tip
Impeller Tlp
Holder
control impeller tip. The impeller tip comes already
l
6
$
.
placed on the units impeller stem (Figure 2).
:
=.
.
:
*
‘.
. .
.-
The impeller tip enables you to control the
r
:
Figure 2’
Impeller Stem
amount of moisture the unit puts into the air. If
you would like to increase moisture output, carefully lift motor
assembly from water reservoir and remove impeller tip and
place on tip holder on under side of humidifier cap. (Figure 3).
figure 3
This enables more water to flow through impeller stem and increases the
amount of moisture that is put into the air. To decrease moisture output just
slide impeller tip back on to impeller stem.
CLEANING INSTRUCTIONS
WARNING: Always unplug humidifier before attempting any service,
especially cleaning.
1.
Periodically, it is imperative to clean impeller, due to the impurities found
in water. Deposits will build up within the impeller stem and limit the
!
moisture output of your humidifier.
2. To clean inside impeller stem, set motor assembly on flat sturdy surface
with impeller stem facing up.
3. Use a small brush or toothpick to clear or loosen any minerals that are
built up in impeller stem.
NOTE: If impeller stem is completely or partially blocked it will inhibit the
performance of the product.