Stow CP-20H Water Pump User Manual


 
STOW CP-20H CENTRIFUGALPUMP — PARTS MANUAL— REV. #0 (05/30/03) — PAGE 13
Figure 2 shows a typical application using the STOW Model CP-20H centrifugal pump. Please note that this pump is intended for
the removal of clean water. This type of pump should only be used for
clear water (no large debris)
applications as it has a limited
solid handling capability of only 10% by volume. DO NOT set strainer on bottom of water bed. Placing the strainer above the water
bed will prevent the pump from drawing in excessive amounts of sand and foreign debris.
1. Pump – The STOW Model CP-20H is 2-inch centrifugal
pump used in general purpose de-watering applications.
Pump should only be used for
clear water
applications
such as agricultural, industrial and residential.
2. Fill Cap – Prior to operation, the pump casing should be
filled with water. Remove this cap to add water to the pump.
After the initial prime, a sufficient amount of water will be
retained in the casing so that the operator will not need to
re-prime later.
If the casing is dry or has insufficient water, the pump will
have difficulty in priming which could lead to premature
mechanical seal wear thus causing damage to the pump.
3. Discharge Port – Connect a 2-inch discharge hose to this
port.
4. Worm Clamp – Used to secure the hose to the inlet and
outlet ports on the pump. Use two clamps to secure the
hose on the inlet side of the pump.
5. Discharge Hose – Connect this flexible rubber hose to
the discharge port on the pump. Make sure that the hose
lays flat and is not kinked. Use only recommended type
discharge hose. Contact Multiquip parts department for
ordering information.
6. Suction Port – Connect a 2-inch inlet hose to this port.
Use two worm clamps to secure the hose.
7. Suction Hose – Connect this flexible rubber hose to the
suction port on the pump. Make sure that the hose lays flat
and is not kinked. Use only recommended type suction
hose. Contact Multiquip parts department for ordering
information
8. Clean-out Cover Handles – To gain access to the pump's
clean-out area, grip both handles, then pull to remove cover.
Make sure both locking knobs have been released before
attempting to remove clean-out cover.
9. Drain Plug – Remove this plug to drain water from the
pump.
10. Clean-out Cover – Remove cover to gain access to the
clean-out area.
11. Locking Knobs– Turn both knobs clockwise to secure
clean-out cover, turn counter-clockwise to release cover.
12. Strainer – Always attach a strainer to bottom side of the
suction hose to prevent large objects and debris from
entering the pump. Strainer should be positioned so that it
will remain completely under water. Running the pump with
the strainer above water for long periods can damage pump.
Figure 2. STOW CP-20H Pump Application
STOW CP-20H — PUMP COMPONENTS