State Industries SUF 100 250NE Electric Heater User Manual


 
ULTRA FORCE
UP TO 96% EFFICIENT COMMERCIAL GAS WATER HEATERS
COMMERCIAL
Other Ultra Force
Features:
Commercial Grade Glass-Lined Tank and
Heat Exchanger for Long-Term Protection
Against Corrosion
• Heat exchanger glass-lined on both water and vent sides to
protect against corrosive flue gases and condensate
Handhole Cleanout
• For easy inspection and cleaning
Meets ASHRAE/IES 90.1-Current Standard Requirements
• Also meets SCAQMD low-NOx Rule 1146.2
• Design-certified by CSA International, according to ANSZ21.10
storage-type water heater standards
Three-Year Limited Tank Warranty
• For complete warranty information, consult written warranty
shipped with water heater or contact State Water Heaters
U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED
MODEL
INPUT
Thermal
Efficiency
Approx.
Capacity
30 Fº 40 Fº 50 Fº 60 Fº 70 Fº 80 Fº 90 Fº 100 Fº 110 Fº 120 Fº 130 Fº 140 Fº
BTUH
KW 17 Cº 22 Cº 28 Cº 33 Cº 39 Cº 44 Cº 50 Cº 56 Cº 61 Cº 67 Cº 72 Cº 78 Cº
SUF 60
120NE
120,000
95%
60 U.S. Gals. GPH 461 345 276 230 197 173 154 138 126 115 106 99
35
227 Litres LPH 1744 1308 1046 872 747 654 581 523 476 436 402 374
95%
100 U.S. Gals. GPH 576 432 345 288 247 216 192 173 157 144 133 123
44
379 Litres LPH 2179 1635 1308 1090 934 817 726 654 594 545 503 467
95%
100 U.S. Gals. GPH 767 575 460 384 329 288 256 230 209 192 177 164
58
379 Litres LPH 2904 2178 1743 1452 1245 1089 968 871 792 726 670 622
95%
100 U.S. Gals. GPH 960 720 576 480 411 360 320 276 262 240 221 206
73
379 Litres LPH 3632 2724 2179 1816 1557 1362 1211 1044 991 908 838 778
96%
130 U.S. Gals. GPH 1164 873 699 582 499 436 388 349 318 291 269 250
88
492 Litres LPH 4406 3304 2644 2203 1888 1652 1469 1322 1201 1102 1017 945
96%
130 U.S. Gals. GPH 1552 1164 931 776 665 582 517 465 423 388 359 332
117
492 Litres LPH 5875 4406 3525 2938 2518 2203 1958 1750 1602 1469 1356 1259
TYPE OF
GAS
NATURAL/
PROPANE
NATURAL/
PROPANE
NATURAL/
PROPANE
NATURAL/
PROPANE
NATURAL/
PROPANE
NATURAL/
PROPANE
Recovery capacities are based on heater performance at 95% and 96% thermal efficiency.
Add “A” to model number when ordering ASME. Optional on SUF 60 120NE - SUF 100 250NE Models. Standard on SUF 130 300NEA and SUF 130 400NEA Models.
Maximum gas supply pressure for 120 - 250: 10.5˝ w.c. natural gas 14˝ w.c propane. Maximum gas supply pressure for 300-400 10˝ w.c. natural gas 13˝ w.c. propane.
Manifold pressure: 4˝ w.c. natural gas 10˝ w.c. propane. Electrical requirements: 120 VAC, Blower 2.2 Amps FL, Igniter 4.0 Amps.
RECOVERY CAPACITY
SUF 60 120NE - SUF 100 250NE Models
SUF 130 300NEA - SUF 130 400NEA Models
150,000
199,900
250,000
300,000
399,900
• Design-certified by Underwriters Laboratories Sanitation to NSF Standard
SUF 100
150NE
SUF 100
199NE
SUF 100
250NE
SUF 130
300NEA
SUF 130
400NEA
5 for 180
o
F (62
o
C) water
195810_SCGSS00207.indd 2195810_SCGSS00207.indd 2 5/30/08 2:46:04 PM5/30/08 2:46:04 PM