State Industries SUF-60-120 Water Heater User Manual


 
ULTRAFORCE COMMERCIAL GAS WATER HEATER
SUF 120 thru 400 SERVICE HANDBOOK
State Water Heaters – Technical Training Department 30 Ashland City, Tennessee © 2009
Servicing should only be performed by a Qualified Service Agent 198152-002
CONTROLS – CONNECTIONS, IGNITER, FLAME SENSOR, SIGHT GLASS, POWERED
ANODES
The connections for the hot surface igniter
and the flame sense rod are shown below.
Also shown is the burner sight glass. These
features are typical for all models.
The new U ltra Force com mercial w ater
heater i s eq uipped w ith pow ered an odes.
These anodes never need replacement. The
CCB monitors the cur rent th rough t he
anodes and will declare a fault if there is a
disconnected wire or if there is no water in
the tank.
Flame
Sensor
Hot Surface Igniter
Burner Mounting
Bolts
Burner Sight Glass
Powered anode connection