TEST 11 - WATER HEATER SHUTTING OFF BELOW SETTING
Conditions:
Main burner ignited
Stored water is below temperature setting more than 5° F (Tank
Average).
Power off
Plug disconnected from heater control board receptacle E3 and E4
TEST 11
WATER TEMPERATURE CIRCUIT CHECK - CONTINUITY
.....neht fI
continuity check pin to pin of lower
temperature probe shows 1 or 0 (E4)
See Test 4
Check wiring and plug connections to heater
control board receptacle E4
Replace lower temperature probe
continuity check red wire pin to red wire pin
on upper temperature sensor shows 1 or 0 (E3)
see Test 4
Check wiring and plug connections to heater
control board receptacle
Replace upper temperature probe
.lortnoc retaeh retaw eht ecalpeR yako era skcehc evoba llA