State Industries SBN71 120 Water Heater User Manual


 
SBN71-120 thru SBN85-390, SBD30-150/199 TANK TYPE COMMERCIAL
GAS WATER HEATER SERVICE HANDBOOK
tnemtrapeD gniniarT lacinhceT83sretaeH retaW etatS
Ashland City, Tennessee 7002 ©
TEST 5 - CALLING FOR HEAT – NO INDUCER OPERATION
Conditions:
Power on
Plugs in Receptacles
Red “ Call for Heat” LED-ON
Inducer “Off”
Note flash code on ignition control board
diagnostic LED
Water Heater Control - Thermostat
“call for heat”
LED Indicator
“diagnostic LED
indicator”
120
........nehtfI
Pin 1 to ground check has no voltage reset control by interrupting power - note
possible reasons for this from flashing LED code
replace ignition board
Pin 1 to ground egatlov sah Proceed
Pin 3 to ground egatlov on sah •check wiring harness and plugs replace inducer