8
ROUGH IN DIMENSIONS
INSTALLATION CONSIDERATIONS
BACK VIEW
K
L
TOP VIEW
F
M
TOP OUTLET
1 1/2" NPT
TOP INLET
1 1/2" NPT
FRONT VIEW
J
B
G
E
D
H
A
C
1 1/2"
NPT
I
TABLE 1. ROUGH-IN-DIMENSIONS
Model Dim.
SBL95 199NE SBL85 275NE(A) SBL85 390NE(A)
inches cm inches cm inches cm
A
B 11 3/4 11 3/4 11 3/4
D 65 3/4 65 3/4 65 3/4
E 25 3/4 25 3/4 25 3/4
F 21 21 21
G 3/4 NPT 3/4 NPT 3/4 NPT
66 1/4 66 1/4 66 1/4
I 6 6 6
J
1 1/2 NPT 1 1/2 NPT 1 1/2 NPT
1 1/2 NPT 1 1/2 NPT 1 1/2 NPT
M 41 104 41 104 41 104
- -
TABLE 2. RECOVERY CAPACITIES, BASED ON 82% EFFICIENCY
Input
BTUH
Input
KW
U.S.
Gal.
Liters Eff. %
U. S. Gallons/Hr. and Liters/Hr. at TEMPERATURE RISE INDICATED
Deg. F 36 40 50 54 60 80 90 100 108 110 120 126 130 140
Deg. C 20 22 28 30 33 39 40 44 50 56 60 61
199000 93 82 545 491 393 364 280 245 218 196 182 164 156 151 140
58 352 2064 1858 1486 1239 1062 1032 929 826 688 619 590 531
85 82 543 502 452 388 339 301 251 226 215 209 194
81 322 2853 2054 1902 1426 1284 1141 951 934 856 815
390000 85 82 1069 962 641 550 534 481 385 356 350 321 305 296
114 322 4046 3641 2913 2081 2023 1820 1618 1456 1349 1324 1214 1156 1120 1040
TABLE 3. GAS AND ELECTRICAL CHARACTERISTICS
Model Gas Type
Gas Supply Pressure
Volts / Hz Amperes
Minimum Maximum
Natural 120/60 <5
FIGURE 6.