State Industries GPG85 740 NEA Electric Heater User Manual


 
For Additional Technical Information,
PHONE 800-365-0024
STATE WATER HEATERS
500 Tennessee Waltz Parkway, Ashland City, TN 37015
www.statewaterheaters.com
SCGSS00205 © 2005 State Industries, Inc. Printed in U.S.A.
March 2007R
For complete information on limited warranties, consult written warranty,
or contact the State Customer Care Center, 1-800-365-0024.
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
TITAN
Low-NOx Commercial Gas Water Heaters
DIMENSIONS AND WEIGHT – ALL MODELS
CAPACITY, INPUT AND OUTPUT
POWERED
BURNER
SUGGESTED SPECIFICATION
Water heater(s) shall be State Model ________________ or equal, with maximum storage capacity of 85
gallons, an input rating of ___________________BTU/Hr., a recovery rating of ____ GPH at 100ºF temperature
rise, and minimum thermal efficiency of 80%. Heater(s) shall meet ASHRAE/IESNA 90.1-1999 requirements for
thermal efficiency and standby loss, and meet SCAQMD R1146.2 low-NOx requirements. In addition, heater(s)
shall: 1) Include a powered gas burner, redundant main gas valves, gas pressure regulator and flame inspection
port. 2) Include a high-temperature limit control, dual-bulb thermostat for accurate temperature control and anti-
stacking compensation and a factory-installed AGA rated temperature and pressure relief valve. 3) Be equipped
with 1-1/2" NPT water inlet and outlet and a boiler-type handhole cleanout. 4) Shall be constructed and stamped
in accordance with ASME Boiler and Pressure Vessel Code and be so marked for a maximum working pressure of
160 psi. 5) Have a glass-lined steel tank with multiple anodes for corrosion protection, and polyurethane foam
insulation. 6) Tank shall have a 3-year limited warranty against corrosion as outlined in the written warranty.
Venting: GPG heater(s) shall be supplied with a Barometric Draft Regulator for conventional atmospheric venting.
GPV heater(s) shall be supplied with an optional vent kit allowing for horizontal sidewall venting or direct venting.
Burner and Controls: Burner(s) shall be pre-mix design, with internal FGR and thermal cutoff, separate spark pilot
ignition system, integral blocked flue sensor, glass view port, main gas regulator, automatic gas valve, manual test
cock and manual gas shutoff. Burner(s) must be factory-installed, tested and started by an Authorized State Start-
up Agent before being placed into operation.
Based on 80% Thermal Efficiency obtained in State engineering laboratories.
To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 5% for every 1,000 feet above sea level.
Current Draw (120V, 60Hz, 1 Phase): 6.0 Amps
*D dimension is for atmospheric vent size (GPG models).
**E dimension is for direct and sidewall vent size (GPV models).
***Minimum gas supply pipe is 1-1/4". See Reference Manual, Table 7 for gas supply pipe size.
MODEL
NUMBER
GPG85 540 NEA
GPV85 540 NEA
GPG85 650 NEA
GPV85 650 NEA
GPG85 740 NEA
GPV85 740 NEA
FIRST
HOUR
RATING
100° F
RISE
583
2206.7
690
2611.7
778
2944.7
TANK
SIZE
85
321.7
85
321.7
85
321.7
BTU
INPUT
PER
HOUR
540,000
650,000
740,000
Gallons
or
Litres
U.S. Gallons
Litres
U.S. Gallons
Litres
U.S. Gallons
Litres
GPH
or
LPH
GPH
LPH
GPH
LPH
GPH
LPH
40°F
4°C
1309
4954.6
1579
5976.5
1794
6790.3
100°F
56°C
523
1979.6
630
2384.6
718
2717.6
140°F
78°C
374
1415.6
450
1703.3
512
1937.9
RECOVERY-GALLONS
PER HOUR AT °F
TEMPERATURE RISE
Inches
or
CM
Inches
CM
950 Lbs.
431.8 Kg
GAS
CONN.***
1
˝
-
A
80-3/4
205.1
B
73
185.4
C
32-1/4
81.9
D
9
22.9
E
26-1/2
67.3
F
26-1/2
67.3
G
93
236.2
H
29-1/2
74.9
I
48-1/2
123.2
DIMENSIONS
SHIPPING
WEIGHT
Page 2 of 2