Actual
Input
Output (Gallons)
Storage
Rating
Ship.
Model Number
Capacity
BTU/Hr.
Firing
Recovery
Dimensions In Inches
Wt. Motor HP
U.S.
Rate
w/Burner 120V 60 Hz 1
Gallons
GPH
80°F Rise 100°F Rise 140°F Rise A B C D E F G H J
(lbs.)
TPD 150 140 ONEA 163 140,000 1 170 136 97 83
1
2 14
1
2 27
3
4 1
1
4 36
1
2 5 47 73 1292
TPD 150 199 ONEA 163 199,000 1.4 241 193 138 83
1
2 14
1
2 27
3
4 1
1
4 36
1
2 6 47 73 1292
1
7 HP - 4.4 Amp
TPD 150 255 ONEA 163 255,000 1.8 309 247 176 83
1
2 14
1
2 27
3
4 1
1
4 36
1
2 6 47 73 1292
TPD 150 270 ONEA 163 270,000 1.9 327 262 187 83
1
2 14 1 27
3
4 1
1
4 36
1
2 657
1
2 73 1397
TPD 150 400 ONEA 151 400,000 2.8 485 387 277 83
1
2 14 1 27
3
4 1
1
4 36
1
2 757
1
2 73 1397
TPD 150 540 ONEA 151 540,000 3.8 654 524 374 83
1
2 14 1 27
3
4 1
1
4 36
1
2 857
1
2 73 1505
TPD 150 720 ONEA 145 720,000 5.1 873 698 416 83
1
2 14 1
1
4 27
3
4 1
1
4 36
1
2 10 57
1
2 73 1510
1
4 HP - 4.6 Amp
TPD 200 300 ONEA 221 300,000 2.1 364 291 208 83
1
2 15 1 32
1
2 1
1
2 44
3
4 666
1
2 73 2098
TPD 200 600 ONEA 221 600,000 4.2 727 582 416 83
1
2 15 1 32
1
2 1
1
2 44
3
4 866
1
2 73 2098
TPD 200 800 ONEA 221 800,000 5.7 970 776 554 83
1
2 15 1
1
4 32
1
2 1
1
2 44
3
4 10 66
1
2 73 2103
TPD 200 1000 ONEA 201 1,000,000 7.1 1212 970 693 83
1
2 15 1
1
4 32
1
2 1
1
2 44
3
4 10 66
1
2 73 2103
1
3 HP - 5.5 Amp
TPD 200 1250 ONEA 201 1,250,000 8.9 1515 1212 866 83
1
2 15 1
1
4 32
1
2 1
1
2 44
3
4 12 66
1
2 73 2467
TPD 200 1500 ONEA 201 1,500,000 10.7 1818 1455 1039 83
1
2 15 1
1
2 32
1
2 1
1
2 44
3
4 12 81
1
2 73 2757
3
4 HP - 10.2 Amp
TPD 300 300 ONEA 300 300,000 2.1 364 291 208 91
1
2 14 1 26
1
2 1
1
2 44
3
4 666
1
2 83 2150
1
4 HP - 4.6 Amp
TPD 300 600 ONEA 300 600,000 4.2 727 582 416 91
1
2 14 1 26
1
2 1
1
2 44
3
4 866
1
2 83 2150
TPD 300 800 ONEA 300 800,000 5.7 970 776 554 91
1
2 14 1
1
4 26
1
2 1
1
2 44
3
4 10 66
1
2 83 2308
TPD 300 1000 ONEA 300 1,000,000 7.1 1212 970 693 91
1
2 14 1
1
4 26
1
2 1
1
2 44
3
4 10 66
1
2 83 2308
1
3 HP - 5.5 Amp
TPD 300 1250 ONEA 300 1,250,000 8.9 1515 1212 866 91
1
2 14 1
1
4 26
1
2 1
1
2 44
3
4 12 66
1
2 83 2584
TPD 300 1500 ONEA 300 1,500,000 10.7 1818 1455 1039 91
1
2 14 1
1
2 26
1
2 1
1
2 44
3
4 12 81
1
2 83 2774
3
4 HP - 10.2 Amp
TPD 400 600 ONEA 411 600,000 4.2 727 582 416 91
1
2 15 1 32
1
2 255876
1
2 81 3207
1
4 HP - 4.6 Amp
TPD 400 800 ONEA 411 800,000 5.7 970 776 554 91
1
2 15 1
1
4 32
1
2 2551076
1
2 81 3212
TPD 400 1000 ONEA 411 1,000,000 7.1 1212 970 693 91
1
2 15 1
1
4 32
1
2 2551076
1
2 81 3212
1
3 HP - 5.5 Amp
TPD 400 1250 ONEA 411 1,250,000 8.9 1515 1212 866 91
1
2 15 1
1
4 32
1
2 2551276
1
2 81 3212
TPD 400 1500 ONEA 397 1,500,000 10.7 1816 1455 1039 91
1
2 15 1
1
2 32
1
2 2551291
1
2 81 3402
TPD 400 1750 ONEA 397 1,750,000 12.5 2121 1697 1212 91
1
2 15 2 32
1
2 2551491
1
2 81 3528
3
4 HP - 10.2 Amp
TPD 400 2000 ONEA 397 2,000,000 14.2 2424 1939 1385 99
1
2 15 2 32
1
2 2551491
1
2 89 3669
TPD 500 2250 ONEA 495 2,250,000 16 2727 2182 1558 110 15 2 32
1
2 2551691
1
2 100 4277
1 HP - 16 Amp
TPD 500 2500 ONEA 495 2,500,000 17.8 3030 2424 1732 110 15 2 32
1
2 2551691
1
2 100 4419
TPD 600 720 ONEA 594 720,000 5.1 873 698 499 119 15 1
1
4 32
1
2 2551076
1
2 109 3667
1
4 HP - 4.6 Amp
TPD 600 1000 ONEA 594 1,000,000 7.1 1212 970 693 119 15 1
1
4 32
1
2 2551076
1
2 109 3667
TPD 600 1250 ONEA 594 1,250,000 8.9 1515 1212 866 119 15 1
1
4 32
1
2 2551276
1
2 109 3667
1
3 HP - 5.5 Amp
TPD 600 1500 ONEA 594 1,500,000 10.7 1816 1455 1039 119 15 1
1
2 32
1
2 2551291
1
2 109 3837
TPD 600 1750 ONEA 594 1,750,000 12.5 2121 1697 1212 119 15 2 32
1
2 2551491
1
2 109 3837
3
4 HP - 10.2 Amp
TPD 600 2000 ONEA 594 2,000,000 14.3 2424 1939 1385 119 15 2 32
1
2 2551491
1
2 109 3837
TPD 600 2250 ONEA 575 2,250,000 16 2727 2182 1558 119 15 2 32
1
2 2551691
1
2 109 4477
1 HP - 16 Amp
TPD 600 2500 ONEA 575 2,500,000 17.8 3030 2424 1732 119 15 2 32
1
2 2551691
1
2 109 4619
TPD Power Dual Fuel Large Volume Commercial Water Heaters
COMMERCIAL
The Expert’s Choice
®
500 Lindahl Parkway, Ashland City, TN 37015 • www.statewaterheaters.com
SPECIFICATIONS
Certified Minimum Installation Clearances to Combustibles:
Front: 18 inches
Back: 0 inches
Sides: 0 inches
Top: 5 inches
A clearance of 24 inches should be maintained from
serviceable parts such as relief valve, power burner, drain
valve and anodes (anodes are located on side above cold
water inlet).
State Titan TPD models are Category I appliances
(Fan Assisted) and require a negative draft. These units
should only be commonly vented with other Category I
negative draft appliances per the latest addition of the
National Fuel Gas Code. An approved/listed Type “B” venting
material is recommended. A negative draft of -0.02˝ to -0.07
is required in the vent.
ASME