State Industries 5 THRU 120 Water Heater User Manual


 
Voltage 120 208 220 240 277 380 415 480 575 600
Fuse Type FNM FNQ-R FNQ-R FNQ-R FNQ-R FNQ-R FNQ-R FNQ-R FNQ-R FNQ-R
VA Secondary Primary
0.6 1.25 0.8 0.6 0.4 0.4
50 (02005006) (02006012) NA NA (02006008) (02006006) NA NA (02006004) (02006004)
2005-6 2006-6 2006-8 2006-6 2006-4 2006-4
1 1.5 1.5 1.5 1.25 0.8 0.8 0.6 0.6 0.6
75 (02005010) (02006015) (02006015) (02006015) (02006012) (02006008) (02006008) (02006006) (02006006) (02006006)
2005-10 2006-15 2006-15 2006-15 2006-12 2006-8 2006-8 2006-6 2006-6 2006-6
1.25 2 2 2 1.5 1.25 1.25 0.8 0.8 0.8
100 (02005012) (02006020) (02006020) (02006020) (02006015) (02006012) (02006012) (02006008) (02006008) (02006008)
2005-12 2006-20 2006-20 2006-20 2006-15 2006-12 2006-12 2006-8 2006-8 2006-8
Fuse Amp rating is shown in bold.
Seattle Part Numbers are shown in ( ).
PSD Part Numbers are shown underlined
Table 2. CONTROL CIRCUIT FUSING
Table 1. ELEMENT CHART AND CONNECTIONS
State Fits Tank State Fits Tank
Part Element Size Part Element Size
Number kW Volts Phase Length (Gals.) Number kW Volts Phase Length (Gals.)
5200 208 1 or 3 60001-4 208 1 or 3
60002-1 2 240 1 or 3 9.5" 5 thru 120 60002-6 9 240 1 or 3 15.5" 20 thru 120
60003-1 480 241.3 mm 60003-6 480§ 393.7 mm
5200-1 208 1 or 3 60001-5 208 1 or 3
60002-2 3 240 1or 3 9.5" 5 thru 120 60002-7 10 240 1 or 3 15.5" 2 thru 120
60003-2 480 241.3 mm 60003-7 480 393.7 mm
60001-1 208 1 or 3 60001-7 208 1 or 3
60002-3 5 240 1 or 3 9.5" 5 thru 120 60002-9 12 240 1 or 3 15.0" 65 thru 120
60003-3 480 241.3 mm 60003-9 480§ 381 mm
60001-2 208 1 or 3 60001-9 208 1 or 3
60002-4 6 240 1 or 3 12.0" 10 tru 120 60002-11 15 240 1 or 3 15.0" 65 thru 120
60003-4 480§ 304 mm 60003-11 480§ 381 mm
60001-3 208 1 or 3 60001-12 208
60002-5 7.5 240 1 or 3 14.5" 20 thru 120 60002-14 18 240 1 or 3 15.0" 65 thru 120
60003-5 480 368.3 mm 60003-14 480§ 381 mm
§ Elements marked 277/480V. Element resistance wires operate at 277V 3Ø due to Y connection on element.