State Industries 201 Series Water Heater User Manual


 
For complete information on limited warranties, consult written warranty,
or contact the State Customer Care Center, 1-800-365-0024.
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
Recoveries are rounded to nearest gallon. For 10-Year Tank and 6-Year Parts Warranty, change "6" to "X" in Model Number (GSX 40 YBRT).
Water Connections – 3/4" male on all models. When ordering Propane, change "Y" to "H" in model number (GS6 40 HBRT).
External heat trap nipples are factory installed on all models.
† Propane Gas – 37,000 input for 50-gallon models, 36,000 input for 40-gallon models.
SELECT
®
Residential Gas Water Heaters
For more information on Select
®
contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800.365.0024 Toll-free USA
www.statewaterheaters.com
SRGSS02408
RESIDENTIAL
State FVIR design meets or exceeds the American National Standards Institute standards (ANS Z21.10.1) that deal with the accidental
or unintended ignition of flammable vapors, such as those emitted by gasoline.
Feature a sealed combustion chamber with air intake filter and a flame arrestor built into the water heater base. In addition, a thermal
cutoff (TCO) device, is designed to shut off gas flow to the burner and pilot if
poor combustion is detected.
Flammable Vapor Ignition Resistant Water Heaters
If flammable vapors accidentally enter the
combustion chamber, the arrestor is designed
so flames burn off the top surface and can not
escape down through the arrestor.
A. Industry standard thermocouple
B. Large View Port for easy burner inspection
C. 360
0
combustion air filter
D. Thermal Cutoff (TCO) with manual reset
C
D
B
A
D
B
A
F
D
1/2" GAS
CONNECTION
T&P VALVE
COLD
CONNECTION
C
E
*Location for optional top-mounted
T&P Valve if ordered from factory.
Maximum Hydrostatic Working Pressure: 150 PSI.
H
OT
CONNECTION
ANODE ROD*
When ordering top-mounted T&P Valve, add "G" to model number (GS6 40 YBRT G).
Propane (LP) models are Series 201
BTU INPUT
RECOVERY
DRAFT
SHIPPING
PER HOUR
90°F RISE
A B C D E F
HOOD
WEIGHT
NATURAL†
GALLONS
OUTLET
(LBS)
DIMENSIONS IN INCHES
SERIES
200
58-1/4
18 13 51-3/4
138
TALL MODELS
SHORT MODEL
HIGH EFFICIENCY MODELS
41
GS6 40 YOCT
20
150
61-3/4 58-1/4
13
51-3/4
1
2
200
PEAK
DEMAND
OUTPUT
(1st Hour
Rating
Gallons)
APPROX
ENERGY
FACTOR
GALLON
CAPACITY
FOAM
THICK-
NESS
(Inches)
MODEL
NUMBER
51-1/2
14140,00040.59
70
200
GS6 40 YBRS
47-3/4
20
13
8 50-1/4
3 or 4
153
20
13 8 41 3 or 4
135
60-3/4
14140,00050.58
88
200
GS6 50 YBRT
57
22
13
8 50-1/4
3 or 4
165
61
24140,000
57-1/4
40,000
50
.62
88
200
GS6 50 YOCT
41
61-3/4
3 or 4
.62
August 2008R
200666_SRGSS02408.indd 2200666_SRGSS02408.indd 2 8/14/08 12:22:44 PM8/14/08 12:22:44 PM