SUGGESTED SPECIFICATION
Figured at 1 kW (3413 BTU) = 4.1 Gallons at 100°F temperature rise.
RECOVERY RATE IN GALLONS PER HOUR AT TEMPERATURE RISE OF
Standard
kW Input
BTU/ Hour
3O
°
F
17
°
C
40
°
F
22
°
C
5O
°
F
28
°
C
60
°
F
33
°
C
70
°
F
39
°
C
8O
°
F
45
°
C
9O
°
F
50
°
C
100
°
F
56
°
C
110
°
F
61
°
C
120
°
F
67
°
C
130
°
F
72
°
C
140
°
F
78
°
C
6 20,478 82
310
62
233
49
166
41
155
35
133
31
116
27
103
25
93
22
85
21
78
19
72
18
66
9 30,717 123
465
92
349
74
279
62
233
53
199
46
174
41
155
37
140
34
127
31
116
28
107
26
100
12 40,956 164
620
123
465
98
372
82
310
70
266
61
233
55
207
49
186
45
169
41
155
38
143
35
133
13.5 46,075 184
698
138
523
111
419
92
349
79
299
69
262
62
233
55
209
50
190
46
174
43
161
40
150
15 51,195 205
775
154
582
123
465
102
388
88
332
77
291
68
258
61
233
56
211
51
194
47
149
44
166
18 61,434 246
930
184
698
148
558
123
465
105
399
92
349
82
310
74
279
67
254
62
233
57
215
53
199
24 81,912 328
1241
246
930
197
744
164
620
140
532
123
465
109
414
98
372
90
338
82
310
76
286
70
266
27 92,151 369
1396
276
1047
221
938
185
609
158
509
138
523
123
465
111
410
101
391
92
340
85
322
79
299
30 102,390 410
1551
307
1163
246
930
205
775
176
665
154
582
137
517
123
465
112
423
102
388
95
358
88
332
36 122,868 492
1861
369
1396
295
1117
246
930
211
798
184
698
164
620
148
556
134
508
123
465
113
429
105
399
40.5 138,226 554
2094
418
1570
332
1256
277
1047
237
897
208
785
185
698
166
628
151
634
138
582
128
537
119
498
45 153,585 615
2326
461
1745
369
1398
307
1163
263
997
230
872
205
755
184
698
168
634
154
582
142
537
132
498
54 184,302 738
2791
554
2094
443
1675
359
1396
316
1196
277
1047
246
930
221
837
201
761
185
696
170
644
158
598
Model
Number
Tank
Capacity
Dimensions
Inlet/
Outlet (NPT)
Approx. Ship.
Wt. (Lbs.)
ABC
gal.
litre
in. cm in. cm in. cm in. cm Ib kg
CSB 52**IFE
50 189
55 3/4
142
21 3/4
55.2
27
68.6
1 1/4
3.2 265 120
CSB 82**IFE
80 300
60 1/4
153
25 1/2
64.8
31
78.7
1 1/4
3.2 280 127
CSB
120**IFE 119 450
62 1/4
158.1
29 1/2
75.0
35
88.9
1 1/4
3.2 390 177
*208 volt models may contain three (3) additional elements. ** Elements available in incoloy only.
kW
Input
Model Numbers
Tank Capacity in Gallons
Number
Of
Elements
Element
Wattage
Full Load Current In Amperes
Single Phase Three Phase
V084V042V802V084V772V042V8029110805
6 CSB 52 6 IFE CSB 82 6 IFE CSB 120 6 IFE 3 2,000 28.8 25.0 21.7 12.5 16.7 14.4 7.2
9 CSB 52 9 IFE CSB 82 9 IFE CSB 120 9 IFE 3 3,000 43.3 37.5 **32.5 18.8 25.0 21.7 10.8
12 CSB 52 12 IFE CSB 82 12 IFE CSB 120 12 IFE 3 4,000 57.7 50.0 43.3 25.0 33.3 28.9 14.4
13.5 CSB 52 135 IFE CSB 82 135 IFE CSB 120 135 IFE 3 4,500 64.9 56.3 **48.7 28.1 37.5 32.5 16.2
15 CSB 52 15 IFE CSB 82 15 IFE CSB 120 15 IFE 3 5,000 72.1 62.5 **54.2 31.3 41.6 36.1 18.0
18 CSB 52 18 IFE CSB 82 18 IFE CSB 120 18 IFE 3* 6,000 86.5 75.0 65.0 37.5 50.0 43.3 21.7
24 CSB 52 24 IFE CSB 82 24 IFE CSB 120 24 IFE 6 4,000 115.4 100.0 86.6 50.0 66.6 57.7 28.9
27 CSB 52 27 IFE CSB 82 27 IFE CSB 120 27 IFE 6 4,500 129.8 112.5 **97.5 56.3 74.9 65.0 32.5
30 CSB 52 30 IFE CSB 82 30 IFE CSB 120 30 IFE 6 5,000 144.2 125.0 **108.3 62.5 83.3 72.2 36.1
36 CSB 52 36 IFE CSB 82 36 IFE CSB 120 36 IFE 6* 6,000 173.1 150.0 130.0 75.0 99.9 86.6 43.3
231451_SCESS00608.indd 2 11/29/10 2:53 PM
The heater(s) shall be SandBlaster CSB Series Commercial Electric Model Number ______________ as manufactured by State Industries shall be rated at
____________kW,_______volts, ____________ phase, 60 cycle AC, and listed by Underwriters’ Laboratories and approved to the NSF Standard 5 by UL. Tank(s) shall
be ________ gallon capacity. Tanks shall be 50, 80 and 119 gallon capacity and shall have 150 psi working pressure and be equipped with extruded high density anode.
Water heater shall have LCD display with built-in diagnostic and troubleshooting information. All internal surfaces of the heater(s) exposed to water shall be glasslined with
an alkaline borosilicate composition that has been fused-to-steel by firing at a temperature range of 1400°F to 1600°F. Electric heating elements shall be gold plated low
watt density screw-in type. Control circuit shall be factory fused and include an immersion thermistor temperature probe with built-in ECO control. All internal circuits shall
be fused. The outer jacket shall be of baked enamel finish and shall be provided with full size control compartment for performance of service and maintenance through
hinged front panel and shall enclose the tank with foam insulation. Electrical junction box with heavy duty terminal block shall be provided. The drain valve shall be located
in the front for ease of servicing. Heater tank shall have a three year limited warranty as outlined in the written warranty. Manufacturer shall supply CSA Certified and ASME
Rated T&P Relief Valve. Fully illustrated instruction manual to be included. Meets standby loss requirements of the U.S. Department of Energy and current edition
ASHRAE/IESNA 90.1.
236828_SCESS00608.indd 2 5/27/11 9:47 AM