Soleus Air PH1-14R-03 Air Conditioner User Manual


 
the lowest and the fan speed at the highest. Reducing the length of the exhaust hoses, insulating the
exhaust hoses, and keeping direct sunlight to a minimum will also improve the cooling efficiency.
DEHUMIDIFYING
1. Properly install the exhaust hoses.
2. Plug the power cord into a grounded outlet.
3. Turn on the unit by pressing the On/Off button on the control panel.
4. Press the Mode button until the “
” icon appears on the multi-color display.
NOTE: The unit operates at low fan speed during dehumidifying. The unit cools the room slightly
during dehumidification.
Keep the windows and the doors closed to aid in the effectiveness of the unit in removing the moisture
from the room.
NOTE: The unit will not dehumidify when the room temperature is lower than 61
°
F.
FANNING
1. Plug the power cord into a grounded outlet.
2. Turn on the unit by pressing the On/Off button on the control panel.
3. Press the Mode button until “
” icon appears on the multi-color display.
4. Select the fan speed by pressing the Fan button.
NOTE: When the unit is running on fan mode, the exhaust hoses are inoperative and are not required.
HEATING
1. Plug the power cord into a grounded outlet.
2. Turn on the unit by pressing the On/Off button on the control panel.
3. Press the Mode button until “
” icon appears on the multi-color display.
4. Press the or button until the desired room temperature appears on the
multi-color display. The temperature ranges from 61
°
F - 88
°
F (16
°
C - 31
°
C).
5. Select the fan speed by pressing the Fan button. It is recommended to use the
low fan speed.
NOTE: When the unit is running on heating mode, the exhaust hoses are inoperative and are not
required.
AUTO MODE
1. Properly install the exhaust hoses.
2. Plug the power cord into a grounded outlet.
3. Turn on the unit by pressing the On/Off button on the control panel.
4. Press the Mode button until the “
” icon appears on the multi-color display.
5. Press the Fan button to select the fan speed.
During the Auto mode, the unit operates in heating mode when the room temperature is below 68
°
F.
The unit operates in dehumidifying mode when the room temperature is between 68
°
F - 73
°
F. The
unit operates in cooling mode when the room temperature is above 73
°
F. You may use the timer with
the Auto mode.
11