Sleep Mode - Press the SLEEP mode button to engage SLEEP mode. Sleep mode automatically rises
the set temperature by 2°F after one hour and 4°F after two hours. This feature limits compressor usage
and enhances energy savings while you are sleeping.
Auto Mode - When AUTO mode is selected the air conditioner will automatically choose the operating
mode base on the current room temperature. When the room is below 68°F the air conditioner will
automatically fan the room to circulate air. When the room temperature is between 68°F-73°F the air
conditioner will operate in Fan mode if it was previously selected or dehumidifier mode (if another mode
was used previously) to remove humidity from the air as well as some cooling to help lower the room
temperature. When the room temperature is between 74°F-79°F the air conditioner will always operate in
dehumidifier mode. When the room temperature rises above 79°F, the unit will operate in air conditioner
mode to maximize cooling. Auto mode uses pre-determined settings to keep you comfortable by choosing
the most energy efficient mode based on the temperature of the room.
10
REMOTE CONTROL OPERATING INSTRUCTIONS (Cont.)