Soleus Air GL-DEH-50-2 50 Dehumidifier User Manual


 
CHOOSING A LOCATION
AUTOMATIC DEFROST
CONTINUOUS DRAINAGE HOSE
A Dehumidifier operating in a basement will have little no effect in drying out an adja-
cent enclosed storage area, such as a closet, unless there is adequate circulation of air
in and out of the area.
Do not use outdoors
This dehumidifier is intended for indoor residential applications only. This unit
should not be used for commercial or industrial applications
Place the dehumidifier on a smooth , level floor surface that is strong enough to
support the unit with a full bucket of water.
Allow at least 12”-18” of air flow on all sides and at least 40” for the exhaust side.
Place the dehumidifier in an area where the temperature will not fall below 41°F.
The coils can become covered with frost at temperatures below 41°F, which may
reduce performance
Use the dehumidifier in cooking, laundry, bathing and dishwashing areas that have
excessive moisture. NOTE: Place the dehumidifier away from a clothes dryer.
Use the dehumidifier to prevent moisture damage anywhere books or valuables are
stored.
Use the dehumidifier in a basement to help prevent moisture damage.
The dehumidifier must be operated in an enclosed area to be most effective.
Close all doors, windows and other outside openings to the room.
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.
When the coils is completely defrosted, the compressor or fan (depending on the model) will automatically restart and
dehumidification will resume.
Water can be automatically emptied by attaching a hose to the continuous drainage port on the side of the dehumidifier. This will
allow the unit to run continuously (depending on the selected humidity level) without having to empty the water bucket. To drain,
simply attach a standard garden hose (not included).
Remove the bucket from the front of the unit.
Open the drain cover on the side of the dehumidifier.
Thread a garden hose (not supplied) onto the nozzle, cut to length and lead to the floor drain.
Replace the bucket in the dehumidifier.
NOTE: The bucket must be in place and securely seated for the dehumidifier to operate.
Above
41° F
YES NO
Below
41° F
Side of Unit
9