Slant/Fin S-60 to S-150 Boiler User Manual


 
S-34 34,000 29,000 25,000 167 80.4 84.0 8
1
8 14
5
8 4_ _
S-60 60,000 51,000 44,000 293 81.6 84.4 11
1
8 17
5
8 4_ _
S-90 90,000 76,000 66,000 440 82.3 84.2 14
1
8 20
5
8 5_ _
S-120 120,000 101,000 88,000 587 83.0 84.1 17
1
8 23
5
8 6_ _
S-150 150,000 125,000 109,000 727 82.4 83.4 20
1
8 26
5
8 7_ _
SX-150 150,000 126,000 110,000 733 82.1 83.2 20
1
8 26
5
8 _647
SX-180 180,000 151,000 131,000 873 82.1 83.1 23
1
8 29
5
8 _748
3
16
SX-210 210,000 175,000 152,000 1013 82.0 83.1 26
1
8 32
5
8 _748
3
16
MODEL
NUMBER †
A.G.A.
INPUT
(Btuh)
D.O.E.
CAPACITY
(Btuh)
NET
I=B=R
RATING
WATER
(Btuh) *
WATER
(Sq.Ft.)
STANDING
PILOT
INTERMITTENT
IGNITION
RATINGS FOR SENTRY BOILERS--NATURAL AND L.P. GAS
EFFICIENCY
(A.F.U.E.%)
DIMENSIONS-Inches
A
B
D
C-VENT DIAMETER
* Net ratings are based on a piping and pick-up allowance of 1.15. Slant/Fin
should be consulted before selecting a boiler for installation having unusual
piping and pick-up requirements.Ratings must be reduced by 4% at 2,000
feet elevation and an additional 4% for every additional 1,000 feet elevation
over 2,000 feet.
†Type of gas:after model number, specify gas by name “Natural” or
“Propane”.
Note: All Sentry boilers are tested and rated for capacity under the U.S.
Dept.of Energy (D.O.E.) Test Procedure for boilers.
C
19
3
/4"
19
3
/4"
19
3
/4"
1
1
/2" Supply
1
1
/2"
Supply
1
1
/2" Supply
3
/4" Drain
3
/4" Drain
3
/4" Drain
3
/4" to air eliminating
system (by others)
3
/4" to air eliminating
system (by others)
3
/4" to air eliminating
system (by others)
Rollout Safety
Switch
(behind
front panel)
Rollout Safety
Switch
(behind
front panel)
Rollout Safety
Switch
(behind
front panel)
Vent Damper*
Vent Damper*
Vent Damper*
Vent Damper*
28
7
/16"
28
7
/16"
32
7
/16"
6
1
/2"
Pressure/Temp.
Gauge
Pressure/Temp.
Gauge
High Limit.
Control
Ignition
Control
High Limit
Control
Ignition
Control
High Limit
Control
Ignition
Control
Blocked Vent
Safety Switch
Blocked Vent
Safety Switch
Blocked Vent
Safety Switch
Supply Piping
(by others)
Supply Piping
(by others)
Combination
Gas Valve
(gas tapping 1/2")
Combination
Gas Valve
(gas tapping 1/2")
Combination
Gas Valve
(gas tapping 1/2")
Ground
Joint Union
Ground
Joint Union
Ground
Joint Union
Circulator:
1/4" Circ. Flange
1
1
/2" Return Tapping
Circulator:
1/4" Circ. Flange
1
1
/2" Return Tapping
Circulator:
1/4" Circ. Flange
1
1
/2" Return Tapping
Sediment Trap
(required)
Sediment Trap
(required)
Sediment Trap
(required)
(Dotted piping
by others.)
(Dotted piping
by others.)
(Dotted piping
by others.)
Integral 
Draft
Diverter
Pressure/Temp.
Gauge
C
A
B
C
A
A
B
B
C
D
INTEGRAL
DRAFT
DIVERTER
EXTERNAL
DRAFT
HOOD
Dimensions
MODELS S-60
to S-150
Dimensions
MODEL S-34
Dimensions
MODELS SX-150
to SX-210
LEFT END VIEW FRONT VIEW RIGHT END VIEW
LEFT END VIEW FRONT VIEW RIGHT END VIEW
LEFT END VIEW FRONT VIEW RIGHT END VIEW
*Vent damper may be installed horizontally on all models with use of a common vent elbow.