Input Voltage: 120V AC, 60Hz
Standby Current: 6mA
Maximum Rating: 2 Amps
Maximum Load: 200W at 120VAC
Operating Frequency: 318MHz
Range: Up to 500 feet in open area
Minimum Load: 10W
Operational Temperature: -4° F - 140° F (-20° C - 60° C)
Humidity: 5%-95%
9. TECHNICAL SPECIFICATIONS
CUSTOMER SERVICE
17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3
Email:support@skylinkhome.com
http://www.skylinkhome.com
P/N. 101Z708
Patent Pending
©2010 SKYLINK GROUP
10. FCC
The Remote Control is approved by the FCC and it complies with Part 15 of the
FCC Rules. Its operation is subject to the following two conditions :
1. This device may not cause harmful interference.
2. This device must accept any interference that may cause undesired operation.
WARNING:
Changes or modifications to this unit not expressly approved by the party responsible
of compliance could void the user’s authority to operate the equipment.
13. ACCESSORIES
8. ERASING TRANSMITTERS FROM THE MODULE
You may erase a transmitter or sensor from the Screw-In Dimmer, but you
cannot erase a specific device directly, you must erase all the wireless
devices, then program the ones you want to keep. Follow the instructions
below to erase programmed transmitters / sensors.
1. Power off the Screw-In Dimmer by switching off the wall switch.
2.
Method 1 (Required the use of a programmed transmitter / sensor):
Transmit a "Erase" code from the transmitter until step 4.
3. Power up the Screw-In Dimmer by switching on the wall switch.
4. You may stop the "Erase" code signal transmission. You have now
successfully erased all the transmitters / sensors.
The Skylink System consists of many other devices such as
SkylinkHome Remotes, Motion Sensor, ON/OFF Wall Switch, Wall Dimmer,
Plug-In Dimmer with or without Repeater, Plug-In ON/OFF Control
(Outdoor/Indoor), Screw-In Dimmer, ON/OFF/Dimming Control, ON/OFF
Control, Smart Button Garage Door Control, etc. Please visit Skylink
website at www.skylinkhome.com for more information.
TM
Home
TM
TM
7. COUNTDOWN TIMER OPERATING MODE
If a Countdown Timer Mode transmitter or sensor is activated, the light
connected to the Screw-In Dimmer will be on for the predetermined time
Interval. During the timer count down, the red LED on the Screw-In
Dimmer will be on steadily. Activating a programmed transmitter or sensor
under Regular Mode or Flashing Alert Mode during timer interval can
override the countdown timer operation.
11. WARRANTY
If, within one year from date of purchase, this product should become defective
(except battery), due to faulty workmanship or materials, it will be repaired or
replaced, without charge. Proof of purchase and a Return Authorization are required.
12. CUSTOMER SERVICE
If you would like to
- find out the up-to-date specifications
- know more about features and applications
- download documents, i.e. user’s instructions
- order Skylink products
or if you have difficulty getting products to work, please:
1. visit our FAQ section at www.skylinkhome.com, or
2. email us at support@skylinkhome.com, or
3. call our toll free at 1-800-304-1187 from Monday to Friday, 9 am to 5 pm EST.
Fax (800) 286-1320
Method 2 (Does not require the use of any transmitter / sensor)
Press and hold the SET button. Do not release the SET button until
step 5.
4. While holding on the SET button, turn on the light and Screw-In Dimmer
by the wall switch. The red LED flashes quickly. You may need another
person helping you to do this.
1. Turn off the light and Screw-In Dimmer by the wall switch.
2. Place the operating mode slide switch to the “Timer” position.
3.
5. You may release the SET button, now you have successfully erased all
the devices.
CAUTION
DO NOT TOUCH ANY METAL PARTS WHILE PRESSING THE SET
BUTTON. MAKING CONTACT WITH INNER METAL PARTS MAY
RESULT IN ELECTRICAL SHOCK CAUSING SEVERE OR FATAL