Simer Pumps 2310 Plumbing Product User Manual


 
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
General Information / Installation 3
ELECTRICAL & SWITCH
SPECIFICATIONS
GENERAL SAFETY INFORMATION
Electrically powered utility pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. See the “Troubleshooting Chart”
in this manual for information about common utility
pump problems and remedies. For more information,
see your retailer, or call Simer customer service at
1-800-468-7867 or 1-800-546-7867.
1. Know the pump application, limitations, and poten-
tial hazards.
2. Do not use in water where fish are present.
3. Disconnect the power before servicing.
4. Release all the pressure within the system before ser-
vicing any component.
5. Drain all the water from the system before servicing.
6. Secure the discharge line before starting the pump.
An unsecured discharge line will whip, possibly
causing personal injury and/or property damage.
7. Check hoses for a weak or worn condition before each
use, making certain that all connections are secure.
8. Periodically inspect the pump and the system com-
ponents. Keep free of debris and foreign objects.
Perform routine maintenance as required.
9. Provide a means of pressure relief for pumps whose
discharge line can be shut-off or obstructed.
10.Personal Safety:
a. Wear safety glasses at all times when working
with pumps.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment.
c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks, mas-
ter switches, and by removing starter keys.
11. When wiring an electrically driven pump, follow all
of the electrical and safety codes that apply.
12.This equipment is only for use on 115 volt (single
phase) and is equipped with an approved 3-conduc-
tor cord and 3-prong, grounding-type plug.
Hazardous voltage. Can shock, burn or
cause death. To reduce the risk of electric shock,
pull the plug before servicing. This pump has not
been investigated for use in swimming pool areas.
The pump is supplied with a grounding conductor
and grounding-type attachment plug. Be sure it is
connected only to a properly grounded grounding-
type receptacle.
Where a 2-prong wall receptacle is encountered, it
must be replaced with properly grounded 3-prong
receptacle installed in accordance with the codes
and ordinances that apply.
Do not walk on wet area until all power has been
turned off. If the shut-off box is in the basement, call
the electric company or hydro authority to shutoff
the service to house, or call your local fire depart-
ment for instructions. Failure to follow this warning
can result in a fatal electrical shock.
Do not lift the pump by the power cord.
13.All wiring should be performed by a qualified
electrician.
14.Make certain the power source conforms to the
requirements of your equipment.
15.Protect the electrical cord from sharp objects, hot sur-
faces, oil, and chemicals. Avoid kinking the cord.
Replace or repair damaged or worn cords immediately.
16.Do not touch an operating motor. Modern motors
can operate at high temperatures.
17.Do not handle the pump or the pump motor, or
change fuses with wet hands or when standing on
wet or damp surface, or in water.
INSTALLATION
1. Set the pump on a hard surface in at least 2 inches
of water.
2. Connect the discharge line with the fittings provided.
3. The pump should not be installed on clay, dirt, mud
or sand surfaces. Although the pump will usually
pass small particles suspended in water, clean the
area to be pumped of small stones and gravel which
could clog the pump.
*NOTICE: Grass, mud, sand or pea gravel can clog the
pump and reduce it’s performance. Keep the pump inlet
screen clean.
4. To reduce motor noise and vibrations when using
rigid pipe, a short length of rubber hose (e.g. radiator
hose) can be connected into the discharge line near
the pump using suitable clamps.
5. Power Supply: These pumps are designed for 115 V.,
60 Hz., operation and requires a minimum 15 amp
individual branch circuit. Pump is supplied with a
3-wire cord with grounding-type plug.
Motor Individual
Model Motor Full Load Branch Circuit
No. HP Amps Req. (Amps)
2300 1/6 5.6 10
2305 1/6 6.0 10
2310 1/6 5.6 10
2355 3/10 10.0 15