Shinco BM Air Conditioner User Manual


 
Shinco Service Manual
- 23 -
151 0.0822 0.0918 0.1025 -10.5% 11.6%
152 0.0805 0.0899 0.1003 -10.5% 11.6%
153 0.0787 0.0880 0.0983 -10.5% 11.7%
154 0.0771 0.0862 0.0963 -10.6% 11.7%
155 0.0755 0.0844 0.0943 -10.6% 11.8%
156 0.0739 0.0827 0.0924 -10.6% 11.8%
157 0.0724 0.0810 0.0906 -10.7% 11.9%
158 0.0709 0.0794 0.0888 -10.7% 11.9%
159 0.0694 0.0778 0.0871 -10.7% 11.9%
160 0.0680 0.0762 0.0854 -10.8% 12.0%
7.2.2 indoor pipe sensor R(0)=188.1K±4% ;B(0/50)3877K±3% R-T datasheet
Temp.() R(min) (KΩ) R(cent) (KΩ) R(max) (KΩ)
ΔR(min) ΔR(max)
-20
510.22 548.83 589.42
-7.0% 7.4%
-19
482.84 518.50 555.89
-6.9% 7.2%
-18
457.10 490.02 524.47
-6.7% 7.0%
-17
432.88 463.28 495.02
-6.6% 6.9%
-16
410.09 438.16 467.39
-6.4% 6.7%
-15
388.64 414.55 441.47
-6.2% 6.5%
-14
368.44 392.35 417.14
-6.1% 6.3%
-13
349.41 371.47 394.30
-5.9% 6.1%
-12
331.47 351.83 372.84
-5.8% 6.0%
-11
314.56 333.34 352.67
-5.6% 5.8%
-10
298.61 315.93 333.72
-5.5% 5.6%
-9
283.56 299.53 315.89
-5.3% 5.5%
-8
269.36 284.07 299.11
-5.2% 5.3%
-7
255.95 269.50 283.32
-5.0% 5.1%
-6
243.28 255.77 268.46
-4.9% 5.0%
-5
231.32 242.81 254.46
-4.7% 4.8%
-4
220.01 230.58 241.27
-4.6% 4.6%
-3
209.31 219.03 228.84
-4.4% 4.5%
-2
199.20 208.13 217.11
-4.3% 4.3%
-1
189.63 197.83 206.06
-4.1% 4.2%
0
180.58 188.10 195.62
-4.0% 4.0%
1
171.49 178.90 186.34
-4.1% 4.2%
2
162.91 170.20 177.54
-4.3% 4.3%
3
154.80 161.98 169.21
-4.4% 4.5%
4
147.14 154.19 161.32
-4.6% 4.6%
5
139.91 146.82 153.83
-4.7% 4.8%
6
133.06 139.85 146.74
-4.9% 4.9%
7
126.59 133.24 140.01
-5.0% 5.1%
8
120.47 126.98 133.62
-5.1% 5.2%
9
114.68 121.05 127.57
-5.3% 5.4%
10
109.20 115.42 121.81
-5.4% 5.5%
11
104.00 110.09 116.35
-5.5% 5.7%
12
99.085 105.03 111.16
-5.7% 5.8%
13
94.425 100.23 106.23
-5.8% 6.0%
14
90.008 95.680 101.55
-5.9% 6.1%
15
85.822 91.355 97.091
-6.1% 6.3%
16
81.851 87.249 92.855
-6.2% 6.4%
17
78.085 83.349 88.825
-6.3% 6.6%
18
74.511 79.643 84.992
-6.4% 6.7%