Sharp IG-CL15U Air Cleaner User Manual


 
E-12
Model
IG-CL15U
Power Supply
120V,60Hz
Fan Speed
HIGH LOW
Power Consumption(W)
17 13
Airow Volume(CFM)
46
(
1.3m
3
/min
)
30
(
0.8m
3
/min
)
Applicable Floor Area(sq.ft)
*1
161
(
15m
2
)
Ion Density(ions/cm
3
)
*2
25,000 7,000
Cord Length(ft)
6.5
(
2.0m
)
Outer Dimensions(in.)
10
1
/
2
(
W
)
x6
1
/
8
(
D
)
x13
(
H
)
Weight(lbs)
7.3
(
3.3kg
)
Problem WHAT TO DO
The Plasmacluster Ion Generator
does not work.
• Make sure to insert the plug.
• Attach lter properly. (See page E-11)
• It’s time to replace Plasmacluster Ion Generating Unit.
Replace with a new Plasmacluster Ion
Generating Unit. (See page E-11)
Plasmacluster Ions are not released. Dust may block the lter,
clean the lter. (See page E-9)
Remove dust from the needle electrode. (See page E-10)
If the lights are still flashing after cleaning filter, unplug and
contact the store you purchased or Sharp service center.
• Filter is getting dirty. Clean the lter.
After cleaning the lter, press Filter Reset
Button for 3 seconds. (See page E-9)
• Conrm the Plasmacluster Ion Generating Unit is set in
correct position. (See page E-11)
• Failure
Unplug the power cord and contact the store you
purchased or Sharp service center.
*1
The applicable floor area for which an emitted airborne ion density of about 25,000 ions/cm
3
can be
measured at a point near the center of the room (at a height of about 1.2m from the oor), during operation
at the HIGH mode when the main unit is placed near a wall. Louvers adjusted to their lowest tilt angle.
*2 Ion count per cm
3
blown into air at around the center of the room (at a height of about 1.2m from the oor)
during operation at each airstream setting when the main unit is placed near the wall. Louvers adjusted to
their lowest tilt angle.
• The number of ions will vary according to the room conditions and operation mode.
TROUBLESHOOTING
Before calling for service, please review the TROUBLESHOOTING chart below.
The problem may not be a unit malfunction.
SPECIFICATIONS
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the wall socket, this
product consumes about 0.4W of standby power.
For energy conservation, unplug the power cord when the unit is not in use.
Flashing (red)
Lighting (orange)
Flashing (red)
Flashing (orange)
Flashing (blue)
Flashing (blue)
Flashing (orange)
Operation_IG-CL15U_EN.indd 12 11.4.13 8:58:20 AM