Sharp AY-XPC12JR Air Conditioner User Manual


 
GB-13
ENGLISH
INDOOR TEMP.
OUTDOOR TEMP.
COOLING
upper limit 32˚C
46˚C (Single use)
43˚C (Multi use)
lower limit 21˚C
–10˚C (Single use)
21˚C (Multi use)
HEATING
upper limit 27˚C 24˚C
lower limit –15˚C
• The built-in protective device may prevent the unit
from operating when used out of this range.
• Condensation may form on the air outlet if the unit
operates continuously in the COOL or DRY mode
when humidity is over 80 percent.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store
settings when a power failure occurs.
After power recovery, the unit will automatically re-
start in the same settings which were active before
the power failure, except for timer settings.
If the timers were set before a power failure, they
will need to be re-set after power recovery.
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start
for two to ve minutes after the unit is turned on to
prevent cold air from blowing out of the unit.
DE-ICING FUNCTION
• When ice forms on the heat exchanger in the
outdoor unit during the HEAT operation, an
automatic de-icer provides heat for about 5 to 10
minutes to remove the ice. During de-icing, the
inside and outside fans stop operating.
• After de-icing is completed, the unit automatically
resumes operation in the HEAT mode.
HEATING EFFICIENCY
• The unit employs a heat pump that draws heat
from the outside air and releases it into the room.
The outside air temperature therefore greatly
affects the heating ef ciency.
• If the heating ef ciency is reduced due to low
outside temperatures, use an additional heater.
• It takes time to warm up and heat the entire room
because of the forced air circulation system.
MAINTENANCE AFTER AIR
CONDITIONER SEASON
1
Operate the unit in the SELF CLEAN
operation to allow the mechanism to
thoroughly dry.
2
Stop the operation and unplug the unit.
Turn off the circuit breaker, if you have
one exclusively for the air conditioner.
3
Clean the lters, then reinstall them.
MAINTENANCE BEFORE AIR
CONDITIONER SEASON
1
Make sure that the air lters are not
dirty.
2
Make sure that nothing obstructs the
air inlet or outlet.
CHANGING THE AIR PURIFYING
FILTER
The lters should be changed every 3 ~ 6 months
1
Remove the air lters.
2
Change the air purifying lters.
1
Take off the old air purifying lters from the
air lters.
2
Set the new air purifying lters, under the
lter stoppers located on the air lters.
3
Reinstall the air lters.
NOTE:
• The dirty air purifying lters are not washable
for reuse. The new lters are available at your
nearest dealer.
Replacement lter: Type AZ-F920F
Disposal of Filters
Please dispose of replaced lters according to the
local disposal laws and regulations.
AIR PURIFYING lter materials
Filter:Polypropylene
Frame:Polyester
Filter stopper
ADDITIONAL NOTES ON
OPERATION
OPERATING TEMPERATURE RANGE