Sharp AY-XP9FR Air Conditioner User Manual


 
AYXP7FR
1 – 1
AYXP7FR
Service Manual
CHAPTER 1. SPECIFICATION
[1] SPECIFICATION
1. AY-XP7FR – AE-X7FR
MODEL INDOOR UNIT OUTDOOR UNIT
ITEMS AY-XP7FR AE-X7FR
Cooling capacity(Min. > Max.) kW 2.1 (0.9 - 2.5)
Heating capacity(Min. > Max.) kW 2.4 (0.9 - 3.4)
Moisture removal(at cooling) Liters/h
Electrical data
Phase Single
Rated frequency Hz 50
Rated voltage V 230
Rated current
(Min - Max.)
Cool A 2.5 (1.0 - 4.1)
Heat A 2.4 (0.9 - 4.5)
Rated input
(Min - Max.)
Cool W 530 (200 - 760)
Heat W 510 (160 - 1100)
Power factor Cool % 92
Heat % 92
Compressor Type Hermetically sealed rotary type
Model DA89X1F-23F
Oil charge 370cc (VG74)
Refrigerant system Evaporator Louver Fin and Grooved tube type
Condenser Corrugate Fin and Grooved tube type
Control Expansion valve
Refrigerant (R410A) 830g
De-lce system Micro computer controled reversed systems
Noise level
(at cooling)
High dB(A) 37 45
Low dB(A)
Soft dB(A) 28
Fan system
Drive Direct drive
Air flow quantity
(at cooling)
High m3/min. 8.0 23.2
Low m3/min. 6.8
Soft m3/min. 5.5
Fan Cross flow fan Propeller fan
Connections
Refrigerant coupling Flare type
Refrigerant tube size Gas, Liquid 3/8", 1/4"
Drain piping mm O.D φ18
Others
Safety device Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters Polypropylene net (Washable)
Net dimensions Width mm 790 730
Height mm 278 540
Depth mm 198 250
Net weight kg 10 33