Sharp AY-X18LCJ Air Conditioner User Manual


 
-25-
Model of Outdoor Unit
AE-X09LCJ
Compressor
Manufacturer/trademark
SANYO
Compressor Model C-6RZ110H1A
Compressor Type Twin rotary
L.R.A. (A) 33
Compressor RLA(A) 4.59
Compressor Power Input(W) 800
Overload Protector Int11l-3979
Throttling Method Capillary throttling
Starting Method Transducer starting
Working Temp Range () -7℃≤T43
Condenser Aluminum fin-copper tube
Pipe Diameter (mm) 9.52
Rows-Fin Gap(mm) 2-1.4
Coil length (l) x height (H) x coil
width (L)
608X508X44
Fan Motor Speed (rpm) 830±20
Output of Fan Motor (W) 30
Air Flow Volume of Outdoor Unit
(m
3
/h)
1800
Fan Type-Piece Axial fan –1
Fan Diameter (mm) 400
Defrosting Method Auto defrost
Climate Type T1
Isolation I
Moisture Protection IP24
Permissible Excessive Operating
Pressure for the Discharge
Side(MPa)
3.8
Permissible Excessive Operating
Pressure for the Suction Side(MPa)
1.2
Sound Pressure Level dB (A)
(H/M/L)
54
Sound Power Level dB (A) (H/M/L) 64
Dimension (W/D/H)( mm) 848X320X540
Dimension of Package
(W/D/H)( mm)
878X360X590
Net Weight /Gross Weight (kg) 40/45
Outdoor
unit
Refrigerant Gas & Charge (kg) R410A / 1.1