Sharp AY-X12NCJ Air Conditioner User Manual


 
16
Installation of Indoor Unit
Earthing Requirements
(1) Mounting plate should be installed horizontally with slight slant to water tray’s outlet for smooth drainage
of water.
(2) Fix the mounting plate on the wall with screws ensuring good fit to wall stud or masonry.
(3) Be sure that the mounting plate has been fixed firmly enough to withstand about 60 kg. Meanwhile, the
weight should be evenly shared by every screw.
Drill Piping Hole
(1) Slant the piping hole (55 degrees) on the wall slightly downward to
the outdoor side.
(2) Insert the piping-hole sleeve into the hole to prevent the connection
piping and wiring from being damaged when passing through the hole.
Installation of Drain Hose
(1) Connect the drain hose to the outlet pipe of the indoor unit. Bind
the joint with rubber belt (tape).
(2) Put the drain hose into insulating tube.
(3) Wrap the insulating tube with wide rubber belt to prevent
the shift of insulating tube. Slant the drain hose downward slightly for
smooth drainage of condensing water.
Note: The insulating tube should be connected reliably with
the sleeve outside the outlet pipe. The drain hose should be
slanted downward slightly, without distortion, bulge or
fluctuation. Do not submerge the outlet in water.
sleeve