Model of Outdoor Unit
AE-X09MCJ
Compressor
Manufacturer/trademark
SANYO
Compressor Model C-6RZ110H1A
Compressor Type Twin rotory
L.R.A. (A) 33
Compressor RLA(A) 4.59
Compressor Power Input(W) 800
Overload Protector Int11l-3979
Throttling Method Capillary throttling
Starting Method Transducer starting
Working Temp Range () -7℃≤T43
Condenser Aluminum fin-copper tube
Rows-Fin Gap(mm) 2-1.4
Coil length (l) x height (H) x coil width (L)
608X508X44
Fan Motor Speed (rpm)
830±20
Output of Fan Motor (W) 30
Liquid line diameter(mm)
Gas line diameter(mm)
Air Flow Volume of Outdoor Unit
(m
3
/h)
1800
Fan Type-Piece Axial fan –1
Fan Diameter (mm) 400
Defrosting Method Auto defrost
Climate Type T1
Isolation
Moisture Protection IP24
Permissible Excessive Operating
Pressure for the Discharge
Side(MPa)
3.8
Permissible Excessive Operating
Pressure for the Suction Side(MPa)
1.2
Sound Pressure Level dB (A)
(H/M/L)
54
Sound Power Level dB (A) (H/M/L) 64
Dimension (W/D/H)( mm) 848X320X540
Dimension of Package
(W/D/H)( mm)
878X360X590
Net Weight /Gross Weight (kg) 40/45
Outdoor
unit
Refrigerant Charge (kg) R410A / 1.1
- 25 -
I
Connection
Pipe
φ6 (1/4")
φ9.52(3/8")