Sharp AE-X24LCJ Air Conditioner User Manual


 
-25-
Model of Outdoor Unit
AE-X24LCJ
Compressor Manufacturer/trademark
SANYO
Compressor Model
C-6RZ146H1A
Compressor Type
Twin Rotary
L.R.A. (A)
41
Compressor RLA(A)
8.4
Compressor Power Input(W)
1640
Overload Protector
1NT11L-3979
Throttling Method
Capillary throttling
Starting Method
Transducer starting
Working Temp Range ()
-15℃≤T46
Condenser
Aluminum fin-copper tube
Pipe Diameter (mm)
Φ9.52
Row-Fin Gap(mm)
2-1.4
Coil length (l) x height (H) x coil width (L)
731X813X44
Fan Motor Speed (rpm) (H/M)
780/620
Output of Fan Motor (W)
60
Fan Motor RLA(A)
0.30
Fan Motor Capacitor (uF)
2.0
Fan Type-Piece
Axial fan –1
Fan Diameter (mm)
460
Defrosting Method
Auto defrost
Climate Type
T1
Isolation
I
Moisture Protection
IP24
Permissible Excessive Operating Pressure
for the Discharge Side(MPa)
3.8
Permissible Excessive Operating Pressure
for the Suction Side(MPa)
1.2
Sound Pressure Level dB (A)
58
Sound Power Level dB (A)
68
Dimension (W/D/H) (mm)
950X340X840
Dimension of Package (L/W/H)(mm)
1100X450X905
Net Weight /Gross Weight (kg)
64/69
Outdoor
unit
Refrigerant Gas & Charge (kg)
R410A/2.4