Notices of Installation
CAUTION
(1) Before installation, please contact your local authorised installer. This unit must be installed by an
authorised installer according to local or government regulations and in compliance with this manual to
avoid a malfunction.
(2) When relocating this unit, please contact your local authorised installer.
(3) Warning: Before obtaining access to terminals, all supply circuits must be disconnected at the circuit
breaker.
(4) If the power cord is damaged, it must be replaced by the installer or authorised service technician in
order to avoid a hazard.
(5) The appliance must be positioned so that the plug is accessible (AYX09 & AYX12 Only).
(6) The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the
copper tube.
(7) This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Installation Site Instructions
Proper installation site is vital for correct and efficient operation of the unit. Avoid the following sites where:
Strong heat sources, vapours, flammable gas or volatile liquids are emitted.
High-frequency electro-magnetic waves are generated by radio equipment, welders and medical
equipment.
Salt-laden air prevails (such as close to coastal areas).
The air is contaminated with industrial vapours and oils.
Corrosion on neighbouring materials exists.
Installation Site of Indoor Unit
The air inlet and outlet should be away from any obstructions. Ensure the air can be blown through the
whole room.
Select a site where the condensing water can be easily drained out, and where it is easily connected for
outdoor unit.
Select a place where is it out of reach of children.
Select the place where the wall is strong enough to withstand the full weight and vibration of the unit.
Be sure to leave enough space to allow access for routine maintenance. The installation site should be
250cm or more above the floor.
Select a place about 1m or more away from TV set or any electric appliance.
Select a place where the filter can be easily taken out.
Make sure that the indoor unit is installed in accordance with the installation instructions.
Installation Site of Outdoor Unit
Select a site where noise and outflow air emitted by unit will not annoy neighbours.
Select a site where there is sufficient ventilation.
Select a site where there is no obstruction blocking the inlet and outlet.
the site should be able to withstand the full weight and vibration of the unit.
Select a dry place, but do not expose the unit to direct sunlight or strong wind.
Make sure that the outdoor unit is installed in accordance with the installation instructions, and access is
convenient for maintenance and repair.
Ensure that the height difference between indoor and outdoor units for the 09K is within 15M, the
12K,18K,24K & 28K is within 10m. Ensure the length of the connection tubing for 09K does not exceed
10m; for 12K does not exceed 20m, for 18K, 24K, 28K does not exceed 25m.
Select a place where it is out of reach of children.
Select a place which will not block pedestrian passage.