Sharp AE-X09LCJ Air Conditioner User Manual


 
-29-
Model of Outdoor Unit
AE-X18LCJ
Compressor Manufacturer/trademark
SANYO
Compressor Model C-6RVN93H0N
Compressor Type twin rotary
L.R.A. (A) 41
Compressor RLA(A) 7
Compressor Power Input(W) 1610
Overload Protector 1NT11L-3979
Throttling Method Capillary
Starting Method Capacitor
Working Temp Range () -7℃≤T43
Condenser Aluminum fin-copper tube
Pipe Diameter (mm) 7
Rows-Fin Gap(mm) 2-1.4
Coil length (l) x height (H) x coil width (L)
806×660×22
Fan Motor Speed (rpm) (H/M/L) 780/600
Output of Fan Motor (W) 60W
Fan Motor RLA(A) 0.26
Fan Motor Capacitor (uF) 3
Air Flow Volume of Outdoor Unit (m
3
/h)
2700
Fan Type-Piece Axial fan –1
Fan Diameter (mm) 460
Defrosting Method Auto defrost
Climate Type T1
Isolation I
Moisture Protection IP24
Permissible Excessive Operating Pressure for the Discharge
Side(MPa)
3.8
Permissible Excessive Operating Pressure for the Suction
Side(MPa)
1.2
Sound Pressure Level dB (A) (H/M/L) 56/54/52
Sound Power Level dB (A) (H/M/L) 66/64/62
Dimension (W/H/D) ( mm) 846X300X685
Dimension of Package (L/W/H)( mm) 994X428X750
Net Weight /Gross Weight (kg) 52/57
Outdoor
unit
Refrigerant Gas & Charge (kg) R410A /1.60