Place a new flat belt onto the motor shaft and pulley.
1
2
3
4
5
Bearing Holder
Groove
Nozzle Head
REPLACEMENT INSTRUCTIONS
Caution: Be sure to turn the ON/OFF switch to the"OFF" position and disconnect the
power cord from the wall outlet before replacing any of the parts below.
REPLACING THE FLAT BELT
Remove the bottom plate.
(refer to page 14)
Lift out the agitator assembly,and then remove the flat belt from the motor shaft and
the agitator pulley.
Place the agitator assembly into the grooves in the nozzle head, making sure that the new
flat belt slides securely into the guide.
Caution:
Install the flat belt so that it has no
twists in it,and so that all components
turn smoothly.
Reattach the bottom plate
(refer to page 14)
13
Motor Shaft
Flat Belt
Pulley
Flat Belt
Agitator Assembly
Motor Shaft
Flat Belt