SECO-LARM USA 190S Home Security System User Manual


 
INSTALLATION HINTS
1. The ENFORCER 190/190S usually receives power from the alarm
panel. If the ENFORCER 190/190S is connected to a separate power
source, it should also be connected to a rechargeable battery, in case
AC power fails.
2. Use either Terminals 2 and 3 N.O. output or 2 and 1 for N.C. output,
but not both.
3. Close all doors and windows when the ENFORCER 190/190S is in
use.
4. Mount any optional memory buzzer, musical device or any sound
generating equipments as far from the ENFORCER 190/190S as
possible to reduce the detector's chance of accidental triggering, and
reducing the chance of a thief finding the ENFORCER 190/190S.
SPECIFICATIONS
POWER: 12VDC (7.5V - 15V)
CURRENT DRAIN (STANDBY CONDITION): 5mA (12V)
CURRENT DRAIN (TRIGGER CONDITION): 80mA (12V)
DETECTOR OUTPUT: DRY RELAY CONTACT, N.O.-C-N.C. (2A)
TAMPER OUTPUT: N.C. CONTACT
YELLOW LED: INDICATES ENVIRONMENTAL NOISE LEVEL
RED LED: INDICATES TRIGGER SIGNAL SENT TO ALARM
TEMPERATURE RANGE: -14°F TO +122°F (-10°C TO +50°C)
CASE CONSTRUCTION: ABS PLASTIC
SIZE: 4.5" x 2.8" x 1.1" (115mm x 70mm x 27mm)
WEIGHT: 3.35oz (95g)
USA PAT. 4700332
UK PAT. 2177797
1041888
TAIWAN PAT.50612
The SECO-LARM policy is one of continual developments and improvements.
For this reason, SECO-LARM reserves the right to change specifications without further notice.
REMARKABLE FEATURES
l YELLOW TURBULENCE LED (PATENTED) ALLOWS FAST AND EASY
SENSITIVITY ADJUSTMENT WITHOUT EXTERNAL TEST METER
l YELLOW LED GIVES PINPOINT SENSITIVITY ADJUSTMENT TO ELIMINATE
FALSE ALARMS
l DETECTS THE HIGH-FREQUENCY SOUND OF GLASS BREAKING
l ENFORCER 190 -- WIDE 25' RADIUS PROTECTION AREA IF
CEILING-MOUNTED, 45' IF WALL-MOUNTED
ENFORCER 190S -- WIDE 20' RADIUS PROTECTION AREA IF
CEILING-MOUNTED, 35' IF WALL-MOUNTED
l RED TRIGGER LED
l TAMPER PROOF CASE
l INSTALLS WITHOUT RF-SHIELDED CABLE
l COMPACT SIZE AND ATTRACTIVE APPEARANCE ALLOWS INSTALLATION
ANYWHERE
HOW IT WORKS
The ENFORCER 190/190S is the most convenient audio-discriminator for glass break
protection on the market today. Designed with the latest technology, it is the installer's
answer to the problem of sensitivity setting and false alarms. A single convenient
ENFORCER 190/190S is enough to protect all the windows and doors within a 15'
radius when mounted on the ceiling, eliminating the need to install unsightly individual
detectors on each pane of glass. Sensitivity setting is extremely simple with
SECO-LARM's Yellow turbulence LED (patented) which eliminates the need for
external test meters. The relay output is programmed for a 2-second reset.
FILE: MI190.P65/MU/DEC1997
ORDER PART# 760-362-1/86C
SECO-LARM
ENFORCER
190 / 190S
GLASS BREAK DETECTOR
ALARM SYSTEMS AND ACCESSORIESALARM SYSTEMS AND ACCESSORIES
ALARM SYSTEMS AND ACCESSORIESALARM SYSTEMS AND ACCESSORIES
ALARM SYSTEMS AND ACCESSORIES
Copyright 1997 SECO-LARM U.S.A., INC. ALL RIGHTS RESERVED.
ENFORCER
®
IS A REGISTERED TRADEMARK OF SECO-LARM
®
SECO-LARM
U.S.A., INC.
17811 Sky Park Circle, Suite D & E,
Irvine, CA 92614
SECO-LARM
Telephone
(800) 662-0800
(714) 261-2999
Fax
(714) 261-7326