Sears 583.35683 Electric Heater User Manual


 
(Pump Rotor, continued)
10.Install blades, pump plate, air
filters, and filter end cover.
11.Replace fan guard and upper shell.
12.Adjust pump pressure (see page 11).
Note: If rotor is still binding, proceed
as follows:
13.Perform steps 1 thru 6 (see page 13).
14.Place fine grade sandpaper (600
grit) on flat surface. Sand rotor
lightly in "figure 8" motion four
times (see Figure 29).
15.Reinstall insert and rotor.
16.Perforln steps 10 thru 12 above.
SPECIFICATIONS
WIRING
DIAGRAMS
Gap Adjusting Screw
.003"/.004" Gap
Measured With
_" Feeler Gauge
Blade
Gap Adjusting Screw
Figure 28 - Gap Adjusting Screw Locations
Sandpaper
\
\\\\
\
Figure 29 - Sanding Rotor
Output Rating (Bin/Hr.)
Fuel
Fuel Tank Capacity (U.S. Gal.)
Fuel Consumption (Gal. Per Hr.)
Electric Requirements
Amperage (Normal Run)
Hot Air Output (CFM)
35,000 55,000 ll0,000
Use Only KeroseneorNo. lFuelOil
3.0 5.0 9.0
.26 .40 .82
120 V/60 Hz(Same All Models)
2.0 2.0 4.5
165 175 490
White
White
Green I I
, _ h I_÷_1 Spark Plug
_lll_¢or I_ I'
Red
Power Plug
120V/60Hz
White__ Black
_- Green
I -I II White
/
I ' II I _ I Fla
rerminall_Blue°BlUelCoCBoardl
Photocell
/
I , II Red IR
Figure 30- Wiring Diagram, 35/55,000 Btu/Hr Models
White
White
Red
Red
Red
Power Plug
120V/60Hz
White__ Black
L Green
- White
_5 BlueoBlue
Red Photocell I_ °
)
rrle-
ut
rrle-
ut
Figure 31 - Wiring Diagram, 110,000 Btu/Hr Model
Reset
Button
Reset
Button
10050u