Sears 449.310311 Water Heater User Manual


 
STEPS TO INSTALL YOUR WATER HEATER (Continued) _.
TIME SWITCH OR OFF PEAK WIRING
For TIME SWITCH or "OFF-PEAK" operation of the lower
elementsee eitherFIG.3E or 3F wiringschematic.
CAUTION: If you are going to wire the unit for either a
TIME SWITCH or "OFF-PEAK" operation, the black wire
from TerminalNo. 4 ofthe limit switch mustbe disconnected
and replaced totally or disconnected and joined with a new
section of wire using a proper connector. BE SURE TO
FOLLOW ALL LOCAL AND NATIONAL CODES AND
ELECTRIC UTILITY REQUIREMENTSWHEN MAKING THE
CONNECTIONS.
Dual element water heaters are designed to allow only one
element to heat at a time. This method is called
non-simultaneous operation and is necessary to avoid
overloading wiring in the house per the National Electric
Code. Off-Peak wiring methods must ensure proper use of
the high limit control in at least one line to each element
and use the non-simultaneous feature.
I _[_al_]_
WARNING
IF YOU ARE NOT FAMILIAR WITH WIRING AND YOU
HAVE ANY DOUBTS, YOU SHOULD GET HELP FROM A
LICENSED ELECTRICIAN. IF YOU DO SOMETHING
WRONG, SEVERE BURN OR SHOCK HAZARDS CAN
RESULT.
REPLACE THE JUNCTION BOX COVER after you have
made the wiring connections.
CAUTION: DO STEP 7, PAGE 6 BEFORE TURNING ON
ELECTRICAL POWERTO THE WATERHEATER.
WIRING
SCHEMATIC
NON-SIMULTANEOUS
OPERATION F,om From
24OV Power Time Clock
BOTTOM ELEMENT Source Switch
ON SEPARATE TIME _ ,_
SWITCH _ =
= .=
tp,'
Water Healsr
Junction Box
kimil SWitCh _
Wpper _ _I
Temperalure"-'_-'_
Control
Thermostat _ t
(SPOT)
Upper Element _ -
Lower
FOR MODEL NOS.
449.310310
449.310311
449.320310
449.320311
449.310410
449.310411
449.320410
449.320411
449.310510
449.310530
449.310531
449.320510
449.320511
CAUTION:
The black wire from
terminal No. 4 on the
Limit Switch must be
disconnected and
reolaced totally or
disconnected and
joined with a new
section of wire. Be
sure to follow all
local and national
codes when maklnQ
this ccnnnecttan.
WIRING
SCHEMATIC
NON-SIMULTANEOUS
OPERATION From From
BOTTOM ELEMENT 2,_v Power"Off-Peak'
Source Meter
ON SEPARATE
"OFF-PEAK" METER _ _=
Water Heater
Junction Box
FOR MODEL NOS.
449.310310
449.310311
449.320310
449.320311
449,310410
449.310411
449.320410
449.320411
449.310510
449.310530
449.310531
449.320510
449.320511
CAUTION:
Thermostat
(EPDT) _ The black wire from
terminal No. 4 on the
Limit Switch must be
Upper Etemant r .j_._ I disconnected and
..... _ realaced totally or
disconnected and
Lower _ ',
Temperature ioined with a new
Conlrol t_ section of wire. Be
Thermostat *' == sure to follow all local
and national codes
_, when makinc this
Lower Eiemenl "------J
- WATER HEATER START-UP.
To comply with safety regulations, the Kenmore Survivor
water heater is factory set to heat water to 120 degrees F. At
this •temperature, water is hot enough for most household : '
needs. A setting of 120° F, or lower if local codes require, is
recommended as a starting point.
Safety and energy conservation are factors to be considered
when selecting the water temperature setting of water heater's
thermostat. The lower the setting the greater the safety and
savings in energy and operating cost.
TIME/TEMPERATURE RELATIONSHIPSIN SCALDS
Time to Produce Serious Burn
More than 5 minutes
11/2to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 11/2seconds
About 1 second
Temperature
120° R
125° E
130° F.
135° R
140° E
145° R
150° R
155° R
Tat_ cour_sy of Sh_ Bum h_st#ute