13. Reinstall battery clamps:
A. Black switch wire damps to positive battery terminal.
B. Black pump wire clamps to negative battery terminal.
NOTICE: DO NOT reverse terminal connections.
14.Turn pump upside down; unclip and remove screen. Do
not remove screw-mounted bottom plate. Lift switch to
momentarily "bump _pump. Check for correct operation
and rotation (pump must rotate counter-clockwise
when looking at end of shaft - Figure 8). If not, reverse
wires to battery and recheck.
15. Replace screen.
16.Plug in charger to wall outlet.
17.Fill sump with water and check switch action. Adjust
tether if necessary.
IA CAUTION IDONOTtest run pump for more than
5 seconds without water in it. Running pump dry for
extended periods could damage pump and voids war-
ranty.
Craftsman Battery Backup Sump Pump
Model 390.306062
6A 6B
12
/
Brown
Negative
Battery Clamp
y Clamp
1412 1194
Key No.
1
2
3
4
5
6A
6B
7
8
9
10
11
12
REPAIR PARTS LIST
Part No. Part Description
PS217-5E
PS17-41
CC0030-13
U17-1148
U17-1149
PS17-100
PS 117-77A
PS22-1
PS78-3P
U78-846P
U78-876P
SwitchAssembly#
PumpComplete***
CordClamp
FuseHolder
15-AmpTime-DelayFuse(2 suppliedt)
WireTerminal(4 Req.)
BatteryTerminalClamps(2 Req.)
BatteryCase(includesstrapandstrapbrackets)
.Charger***
CheckValve
HoseClamp1"min.- 2"max.S.S.
PipeAdapter
Tee 1-1/2x 1-1/2x 1-1/4 PVC
ReducerBushing(2 Red.)
# When ordering,alsoorderKeyNos.4 (FuseHolder)and5 (Fuse)requiredfor installation.
* Notillustrated.
** StandardHardwareItem;purchaselocally.
*** Nocomponentpartsavailablefor pumporbatterycharger.
1 Secondfuse issuppliedas spare.