SERVICE
VERTICAL SWITCH REPLACEMENT
Model 390.304692
VERTICAL SWITCH REPLACEMENT
Models 390.30479 and 390.30579
_y
(_ Mount lhe bracket Brackel
onlo the switch Br_ckel
housing Mounting
I Screws Switch
Housing
Siip the [_o_l
onto the rod
(_ Screw the rod
stop onto the _ (AI
end o[ the lod Rod
FlOat _ "
Stop ._ (B)_
Inset1 the rod assembly
(_ up into the switch
housin 9 (A) and _ock
into place with the
pin (5_). See the inset
drawing
(_ Attach the swilch to
the pump as shown
Inset Drawing
!
i
Float
Rod ,_
to Bottom of
Pump
CAUTION j Make sure pin holds float rod in switch
housing; otherwise pump will not shut off.
To check switch operation, run pump through one com-
plete cycle after installation.
[_- WARNINGj Risk of electrical shock. Can burn or kill.
Plug pump and switch into a grounded electrical outlet
only,
A CAUTION 1 Make sure pin holds float rod in switch
housing; otherwise pump will not shut off.
To check switch operation, run pump through one com-
plete cycle after installation.
I_" WARNINGI Risk of electrical shock. Can burn or kill
Plug pump and switch into a grounded electrical outlet
on/y o