Sears 1F86-382 Thermostat User Manual


 
Seal
HomeServices
1-800-4-MY-HOME
1F86-382
Non-Programmable Electronic Digital Thermostat
iNSTALLATiON AND
OPERATION iNSTRUCTiONS
__hese instructions for fu__
FAILURE TO READ AND FOLLOW ALL iNSTRUCTiONS CAREFULLY
BEFORE iNSTALLiNG OR OPERATING THiS CONTROL COULD CAUSE
PERSONAL iNJURY AND/OR PROPERTY DAMAGE,
DESCRiPTiON
Your new Digital Thermostat uses the technology of a solid-state
microcomputer to provide precise temperature control.
Features:
Simultaneous heat and cool setpoint storage
Pre-set temperature control
Backtit display
LCD continuously displays setpoint and room temperature
°F/°C convertibility
Temperature range 45° to 90°F
RC, RH, C, W, Y, G, O and B terminals
Optional C terminal (Dual Power option)
B and O terminals for single stage heat pumps (no auxiliary
heat) or damper operation
Setpoint storage in case of power loss
2 "AA" alkaline batteries included
PRECAUTIONS
This thermostat is intended for use with a tow voltage system;
do not use this thermostat with a line voltage system. If in doubt
about whether your wiring is mitlivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contrac-
tor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could
cause the control to malfunction.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installati on and all components of the sys=
tern shall conform to Class II circuits per the NEC code.
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
SPECIFICATIONS
ELECTRICAL DATA APPLICATIONS
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 150°F
For use with:
Standard heat/cool or heat only systems
Electric heat systems
Gas or oil fired systems
Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
Hydronic (hot water or steam) systems
Single-stage heat pump systems (no auxiliary heat)
o Mitlivolt systems
DO NOT USE WITH:
Multi-stage systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
PART NO. 37-6925A
0811