Sears 139.53636SRT Garage Door Opener User Manual


 
Insertthewireconnectorintoeach
sensorandpushuntilyouheara
click,Figure6.Thewhitetabonthe
sensorshouldbeflushwiththeback
oftheconnector.
Figure 7
Safety Sensor
Wire Connector "
Figure 6
< _ Tab shoutd be
J I flush with back
onnector
/
Push connector in
until you hear a click
BelI Wire
Connect Wire to
Opener Terminals
__ Finished __ o._.--"_ "__
Cei,ing .......... _
Sensor
Connections
Betl Wire
OPENER TERMINAL SCREWS
Center each sensor unit in a "C" wrap with lenses
pointing toward each other across the door.
Secure sensors with the hardware shown. Finger
tighten the wing nut on the receiving eye to allow
for final adjustment. Securely tighten the sending
eye wing nut.
Wing Nut
"C" j.Wire
Invisible Light Beam
Sensor Protection Area
/
Sensor
Sensor
Run paired wires from both sensors to the opener.
Trouble Shooting
Indicator Light
1/4-20x 1-1/2"
Hex Bo(t
Use insulated staples to secure wire to wall and
ceiling.
Strip 1/4" of insulation from each set of wires.
Separate white and white/black wires sufficiently to
connect to the opener terminal screws: white to 2
and white/black to 3.
Plug in the opener. Make sure the Lock Feature is
off. Green indicator lights in both the sending and
receiving eyes will glow steadily if wiring
connections and alignment are correct.
If the indicator light is offin the receiving eye (and
the invisible light beam path is not obstructed),
alignment is required.
Loosen the receiving eye wing nut to allow slight
rotation of unit. Adjust sensor vertically and/or
horizontally until the green indicator light glows
with a steady lighL
When indicator lights are glowing steadily in both
units, tighten the wing nut in the receiving eye unit.
1. If the sending eye indicator light does not glow
steadily after installation, check for:
Electric power to the opener.
A short in the white or white/black wires. These
can occur under staples or at screw terminal
connections.
Incorrect wiring between sensors and opener.
An open wire (wire break).
2. If the sending eye indicator light glows steadily but
the receiving eye indicator light doesn't:
Check alignment.
Check for an open wire to the receiving eye.
Hardware Shown Actual Size
1/4-20x 1-1/2"
Hex Bott
23