Sears 113.17066 Vacuum Cleaner User Manual


 
6
Float/Cage Assembly
1. Remove the detachable blower from
the power head assembly by pressing
down on the power head latch
beneath the carry handle of the
detachable blower. Set the detachable
blower off to the side. Place lid upside
down on the drum.
2. Locate the float and filter cage.
3. Place the float over the opening in the
center of the lid with the words "This
Side Towards Lid" laying face down
over the hole. (See illustration.)
4. Line up filter cage tabs, as shown,
with the slots in the center ring of the
lid assembly. Push on the filter cage
until the tabs snap into slots for a
secure fit.
NOTE: If filter cage needs to be
removed, or replaced, because the float
is placed in the wrong way, use a flat
blade screwdriver and insert the blade
near one of the tabs between the filter
cage and the center ring of the lid. Pry
the tab out of the slot. Tilt the cage and
lift away from the lid. To replace, follow
Float/Cage Assembly instructions.
WARNING: For your own safety,
never connect plug to power source
outlet until all assembly steps are com-
plete and you have read and under-
stood the safety and operation instruc-
tions. Do not operate vac with any
parts damaged or missing.
WARNING: To avoid personal injury
or damage to vac be sure to keep
hands, fingers, or any other foreign
objects out of the center opening when
assembling the float .
Filter Cage
Tabs (3)
Float
Solid End
Power
Assembly
Slots (3)
THIS SIDE
TOWARD LID
Filter Cage
Tabs (3)
Slots (3)
Power Head
Assembly
Carry Handle
Power Head
Latch
SP6570 16 gallon detach 12/8/04 8:47 AM Page 6