SeaLand 3000 Indoor Furnishings User Manual


 
10
MANUAL FLUSH OPERATION
In the event of an electrical failure, the ush ball can be manually operated to clear the bowl. We recommend using
a long-neck screwdriver or 7/16-in. socket for the operation shown below. NEVER PRY OPEN THE FLUSH BALL
FROM INSIDE THE TOILET BOWL. Damage to the ush ball and bowl seals may result.
2. Locate hole on left side
of china toilet. This al-
lows access to the ush
valve motor drive arm.
3. Insert screwdriver or
7/16-in. socket through
access hole and onto hex
head.
4. Turn screwdriver or
socket wrench counter-
clockwise. This will open
ush ball and allow bowl
contents to clear. After
bowl is clear, turn screwdriver or socket wrench clockwise
to return ush ball to original position.
1. Remove PC board
access cover. Place
Mode Switch in the
“Manual Override” posi-
tion. This disconnects
ush valve motor brake
from electrical circuit.
NOTES:
Water will not enter the toilet bowl during manual ush
operation.
Place Mode Switch in the “Normal” position before
returning to automatic operation.
Manual Override
position
TOILET SYSTEM ELECTRICAL SPECIFICATIONS
12VDC 24VDC
Maximum standby current (amps): .080 .080
Maximum operating current (amps): 6.5 2.5
Flush motor locked rotor current (amps): 14.5 7.25
Maximum voltage 15 30
Minimum voltage: 10 20
Input power wire size 14 ga. 14 ga.
All other wires size: 18 ga. 18 ga.
Fuse size (amps) 8 4
NOTES: Standby current includes ush panel status light.
Operating current does not include vacuum pump or other sanitation system components.