Scotsman Ice C1448 Air Cleaner User Manual


 
Plumbing Requirements
All models require connection to cold, potable
water. A hand actuated valve within site of the
machine is required. Air cooled models have a
single 3/8” FPT inlet water connection, a 3/8” FPT
to 3/8” male flare adapter is supplied with the
machine and can be used if desired.
Water cooled models have the same inlet fitting
plus an additional 3/8” FPT condenser inlet water
connection.
Water Filters
If connecting to water filtration, filter only the water
to the reservoir, not to the condenser. Install new
cartridges if the filters were used with a prior
machine.
A triple head filter is recommended. Either the
Scotsman SSM3 taste and odor filter system, or
the ADS-AP3 Aqua Patrol system.
November 2006
Page 10
C1448, C1848, C2148W
Air and Water Cooled User Manual
Water Fitting
Inlet Water
Connection