Sanyo SAP-KRV93EH Air Conditioner User Manual


 
35
HIGH POWER
This function acts to raise the power but keeps the AC system in
the same operating mode.
This function is set with the HIGH POWER button on the remote
controller.
(It can be set regardless of the temperature and fan speed
settings.)
HIGH POWER operation from remote controller
The unit operates at maximum output for 30 minutes,
regardless of the desired temperature.
The fan speed is 1 step above “High.”
Lamp colors
OPERATION lamp
NIGHT SETBACK
NOTE
When HIGH POWER operation ends, the unit operates at low
Hz for 5 minutes, regardless of the thermostat OFF conditions.
When in DRY mode, operation is in the cooling zone.
Timer backup
Operation stops if there are no operator controls for 25 hours or
longer after unit operation switched from OFF to ON by use of
ON timer operation.
Frequency
MAX
0
Start End
Time
30 min. 5 min.
When NIGHT SETBACK operation is set, the temperature and
fan speed settings will be adjusted automatically to allow
comfortable sleep.
When NIGHT SETBACK operation is set, “ mark” appears on
the remote controller. The main unit display lamp also becomes
dimmer.
COOL and DRY modes
The indoor unit fan speed is automatically lowered for quiet
operation.
The temperature setting is raised by 1°C 30 minutes after
NIGHT SETBACK operation is set. This repeats again after
another 30 minutes have passed to gradually raise the
temperature.
HEAT mode
The indoor unit and outdoor unit fan speeds are
automatically lowered for quiet operation.
The temperature setting is lowered by 2°C 30 minutes after
NIGHT SETBACK operation is set.
This repeats again after another 30 minutes have passed to
gradually lower the temperature.
TIMER lamp Green
QUIET lamp Green
HEAT operation Red
DRY operation Orange
COOL operation Green