Sanyo SAP-KRV123EH Air Conditioner User Manual


 
25
Troubleshooting
If your air conditioner does not work properly, first check the following points before requesting service. If it still does
not work properly, contact your dealer or service center.
Operating Range
The air conditioner is operable within the temperature ranges as listed below:
Trouble Possible Cause Remedy
Air conditioner does not run at all. 1. Power failure. 1. Restore power.
2. Leakage circuit breaker tripped.
2. Contact service center.
3. Line voltage is too low. 3. Consult your electrician or dealer.
4. Batteries in remote control unit
have run down.
4. Replace batteries.
OPERATION lamp blinks and air
conditioner does not operate.
Trouble in system. Contact service center.
Compressor runs but soon stops. Obstruction in front of condenser coil. Remove obstruction.
Poor cooling (or heating)
performance.
1. Dirty or clogged air filter. 1. Clean air filter to improve airflow.
2. Heat source or many people in
room.
2. Eliminate heat source if possible.
3. Doors and/or windows are open. 3. Shut them to keep the heat (or
cold) out.
4. Obstacle near air intake or air
discharge port.
4. Remove it to ensure good airflow.
5. Thermostat is set too high for
cooling (or too low for heating).
5. Set the temperature lower (or
higher).
6. (Outdoor temperature is too low for
heating.)
6. (Consult your dealer or try to use
another heat appliance.)
Clicking sound is heard from the air
conditioner.
In heating or cooling operation, any
plastic parts may expand or shrink
due to a sudden temperature change.
In this event, a clicking sound may
occur.
This is normal, and the sound will
soon disappear.
OPERATION lamp lights but outdoor
unit will not run.
1. The use of cellular phones near
the air conditioner may cause
disturbance to its normal
operation.
1. Turn off the power then restart the
air conditioner after a while.
2. Consult your dealer.
Temperature Indoor air temperature Outdoor air temperature
COOLING Max. 32 °C DB / 23 °C WB 43 °C DB
Min. 19 °C DB / 14 °C WB 19 °C DB
HEATING Max. 27 °C DB 24 °C DB / 18 °C WB
Min. 16 °C DB –8 °C DB/ –9 °C WB