Sanyo KHS1271 Air Conditioner User Manual


 
Indoor Unit : KHS1271
Outdoor Unit : CH1271
Power Supply : 115V Single Phase 60Hz
< Heating Capacity >
TH : Total Heating Capacity (BTU/h)
1.
Rating conditions (#)
: Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.
: Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.
2.
3. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air
Prevention Protection during heating operation into account. For this reason, the value may vary
from the actual heating characteristics.
NOTE
RATING CAPACITY: 14,300 BTU/hAIR FLOW RATE: 312 CFM
OUTDOOR INDOOR
ENT. TEMP.
o
F (
o
C) AMBIENT TEMP.
o
F (
o
C)
W.B. 60 65 70 75 80
(15.6) (18.3) (21.1) (23.9) (26.7)
0 (-17.8) TH 8,010 8,000 7,980 7,960 7,930
3 (-16.1) TH 8,280 8,270 8,250 8,230 8,200
8 (-13.3) TH 8,930 8,910 8,890 8,870 8,840
13 (-10.6) TH 9,600 9,580 9,560 9,530 9,500
18 (-7.8) TH 10,330 10,310 10,290 10,260 10,220
23 (-5.0) TH 11,100 11,080 11,050 11,020 10,980
28 (-2.2) TH 11,900 11,870 11,840 11,800 11,760
33 (0.6) TH 12,720 12,690 12,660 12,610 12,560
38 (3.3) TH 13,530 13,500 13,460 13,410 13,360
43 (6.1) TH 14,380 14,350 # 14,300 14,250 14,190
48 (8.9) TH 15,240 15,200 15,150 15,090 15,020
53 (11.7) TH 16,090 16,050 15,990 15,920 15,850
58 (14.4) TH 16,910 16,850 16,790 16,720 16,640
63 (17.2) TH 17,730 17,670 17,600 17,520 16,690
65 (18.3) TH 18,040 17,980 17,910 17,480 16,620
25